10
Command 34
Emergency Button Enable
The
Help Button
can be enabled or
disabled to send an Emergency alarm
report:
Function Selection
Result
(0)
OFF
(Disable)
(1)
ON
(Enable)
Factory Default
is
set as
(1), ON
.
OFF
: Pressing the
Help Button
is unable
to send an emergency alarm.
ON
: Pressing the
Help Button
will activate
the panel send an emergency alarm.
Command 35
Silent Mode
CTC-1052-QT-DT35AW can be selected to
operate in Silent Mode. This will mute all
normal operation
warning beeps
,
guard
time tone
and
key tone
.
<NOTE>
Speech Reporting made under Silent
Mode will automatically be switched to
Listen-in, but call recipient can press
DTMF
keys
to
open
two-way
communication or change modes.
If
Command #31
is set as
Enable
,
CTC-1052-QT-DT35AW will emit ring
tone for incoming calls even in silent
mode.
Silent mode will not mute the long beep
emitted during walk test.
Function
Selection
Result
(0)
ON
(Silent)
(1)
OFF
(Normal)
Factory Default
is set as (
1
),
OFF
.
Command 37
AC Fault Report
The
CTC-1052-QT-DT35AW
can
be
programmed to send a Fault Report when
an AC power failure is detected.
Function Selection
Result
(0)
OFF
(Send No Report)
(1)
ON
(Send Report)
Factory Default
is set as (
1
),
ON
.
<NOTE>
Reporting will only be made after
detecting
AC
Fault
condition
continuously for one hour.
Command 38
Follow-On & Call-Back Function
Function Selection
Result
(0)
Follow-On
(Reserved)
(1)
Call-Back
(2)
Follow-On & Call-Back
When this function is programmed as (
1
),
after a successful reporting to the
Monitoring Center, CTC-1052-QT-DT35AW
will automatically hang up the line and start
a 5-minute waiting period to auto answer
any incoming phone calls from the
Monitoring Center.
When this function is programmed as (
2
),
after a successful reporting to the
Monitoring Center, CTC-1052-QT-DT35AW
will automatically enter the Follow-On
mode.
Once Follow-On Mode is terminated, CTC-
1052-QT-DT35AW will automatically start a
5-minute waiting period to auto answer any
incoming phone calls from the Monitoring
Center.
When the Monitoring Center calls back
within the 5-minute period (when call back
Содержание CTC-1052-QT-DT35AW
Страница 1: ...CTC 1052 QT DT35AW User Manual Dec 18 2020...