background image

www.directed.com

36

remote control sensor disable

1.

Arm the system.

2.

Use the transmitter to bypass the sensor.

3.

The lights will flash four times. All warn away zones are now bypassed.

4.

Transmit the sensor bypass channel again.

5.

The lights will flash four times again. The sensor warn away and full trigger
zones are now bypassed.

6.

The sensor zones will reset when disarmed.

troubleshooting

Starter kill does not work. 

z

Is the correct starter wire being interrupted? If the car starts when the starter kill
relay is completely disconnected, the wrong starter wire has been cut and inter-
rupted. 

z

Is the YELLOW wire seeing true ignition? Is it connected to an accessory circuit?

z

Has the no/nc feature been changed?

Shock sensor does not trigger the alarm. 

z

Has the FACT II system been triggered? To check this, turn the ignition key on
and off to clear the FACT II from memory, and then retest the shock sensor. For
a detailed description of FACT II, see the 

FACT II: False Alarm Control

Technology section of this guide.

Closing the door triggers the system, but opening the door does not. 

z

Have you correctly identified the type of door switch system? This happens often
when the wrong door input has been used.

The system will not passively arm until it is remotely armed and then disarmed. 

z

Are the door inputs connected? Is a BLUE wire connected to the door trigger wire
in the vehicle? Either the GREEN H1/9 or the VIOLET H1/8 should be used
instead.

Содержание ARROW 5

Страница 1: ...2004 Directed Electronics Inc Vista CA N909595 08 04 installation guide...

Страница 2: ...ases or words Bitwriter Code Hopping DEI Directed Doubleguard ESP FailSafe Ghost Switch Learn Routine Nite Lite Nuisance Prevention Circuitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle...

Страница 3: ...tiplex 18 type H negative multiplex 19 peripheral plug in harnesses 20 super bright blue led 2 pin white plug 20 plain view valet 20 sensor harness 4 pin connector 21 mounting the receiver antenna 21...

Страница 4: ...receiver z One three pin door lock harness with harness z One Owner s Guide z One pre wired blue status LE z Two window decals z One PlainView 2 Valet switc z Warranty registration card z One 514C Ne...

Страница 5: ...orrespond to a standard configuration transmitter standard configuration Button The arming disarming and panic function are controlled by this button Button The trunk release or accessory output is co...

Страница 6: ...Please read the instructions carefully to ensure a thorough understanding of this unit and how it operates YELLOW Ignition Input ORANGE Ground When Armed RED WHITE Accessory Output A BLACK WHITE Dome...

Страница 7: ...ecurity components be grounded at the same location h1 7 blue hood trunk trigger input zone 5 This input will respond to a negative input with an instant trigger It is ideal for hood and trunk pins an...

Страница 8: ...Connect to the battery pos itive terminal be sure to use the supplied fuse holder and a 5 amp fuse or the con stant 12V supply to the vehicle fusebox h1 11 brown siren output Connect the BROWN siren o...

Страница 9: ...o it I IM MP PO OR RT TA AN NT T The polarity of this wire is determined by the connection of the H1 12 light flash input wire Always confirm light flash polarity before connecting H1 12 or damage to...

Страница 10: ...n only supply 200 mA of current Connecting directly to a solenoid motor or other high current device will cause it to fail h1 17 orange ground when armed This wire provides a ground output as long as...

Страница 11: ...connections as described in the following diagram Connect H2 1 to the end of the wire that is still connected to the ignition switch con nect H2 2 or H2 3 to the end of the wire that continues to the...

Страница 12: ...s that pulse 12 volt alter nately on lock and unlock make sure that it is not a Type C direct wire system Here is a test Cut the wire that pulses 12 volt on lock and then operate the switch to unlock...

Страница 13: ...se locking are high current so a 451M or 2 relays need to be used The switch will have three wires on it and one wire will test ground all the time One wire will pulse negative when the switch locks t...

Страница 14: ...res The switch that lost all operation is the master switch If one switch works in both directions and the other switch works in only one direction you have a Type A system If both switches still oper...

Страница 15: ...ed Vehicles without factory power door locks require the installation of one actuator per door This requires mounting the door lock actua tor inside the door Other vehicles may only require one actuat...

Страница 16: ...from the passenger key cylinder If all the doors lock the vehicle s door lock system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 1...

Страница 17: ...cutting the wire to lock the door In some vehicles these functions are reversed Type F door locks are found in late model Nissan Sentras some Nissan 240SX and Nissan 300ZX 1992 up They are also found...

Страница 18: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse 12 volt in one direction and less than 12 volt when operated in...

Страница 19: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse ground in one direction and resistance to ground when operated i...

Страница 20: ...s into a 5 16 inch mounting hole If flush mounting the LED from the back of a panel drill a mounting hole using a 17 64 inch drill bit Be sure to check for clearance prior to drilling the mounting hol...

Страница 21: ...iver antenna is centered high on either the front or rear windshield For optimal range the antenna should be mounted vertically It can be mounted horizontally in relation to the windshield or under th...

Страница 22: ...ted by an addition al set of status chirps called Malfunction AutoBypass The specific zone bypassed is then reported by the LED For more zone information refer to Table of Zones section of this guide...

Страница 23: ...stored in memory the LED will blink continuously until the system is armed disarmed using the transmitter after recalling the final trigger For more information please refer to the Table of Zones sect...

Страница 24: ...Valet The Installer Selectable Features grid allows the installer to change input output functions of the system to integrate with the vehi cle s specific characteristics cliffnet wizard pro installat...

Страница 25: ...Feature select Press the same number of times as the desired feature The siren will chirp with each press The feature can now be changed using the remote control 6 Feature change Press the arm disarm...

Страница 26: ...two chirps and the lights will flash The system will arm 25 seconds later z Off The transmitter must be used to arm the system chirps on off quiet z On Chirps will sound when arming disarming the syst...

Страница 27: ...rned off passive lock on off z On The doors will lock when the system passively arms This feature only applies when passive arming is programmed on z Off The doors will not lock when the system passiv...

Страница 28: ...et on off z On The alarm can be put into valet mode with the remote control z Off The alarm can not be put into valet mode with the remote control entry delay on off z On If the system has passively a...

Страница 29: ...programmed into this feature will arm disarm the system but the siren will not chirp remote valet z The transmitter channel programmed into this feature will make the system enter exit valet mode remo...

Страница 30: ...ase the button You have now entered the feature selection posi tion of the Installer Selectable Features grid P1 Pulsed channel output is disabled with the ignition on or the alarm is armed P2 Pulsed...

Страница 31: ...armed z Off Malfunction autobypass chirps will be generated if any door triggers or the delay domelight are active when the system is armed accessory output programming The auxiliary accessory output...

Страница 32: ...ircuit is normally closed and power is lost to the system the circuit will close and the starter will operate normally rpm programming z This feature applies only if IntelliStart 4 is installed z Prog...

Страница 33: ...on firm the transmitter channel has been programmed z For the rest of the channels the siren will chirp the same number of times as the feature row N NO OT TE E When programming a new transmitter to c...

Страница 34: ...e user selectable programming grid 2 Immediately press and release of the PlainView 2 Valet switch 3 Select each digit by pressing 1 9 times and then press to enter the number into the system To enter...

Страница 35: ...ts over FACT II will also bypass warn away triggers for the 60 minute duration FACT II requires that you change the way you test the system once you have it installed Resetting FACT II requires the 60...

Страница 36: ...ue ignition Is it connected to an accessory circuit z Has the no nc feature been changed Shock sensor does not trigger the alarm z Has the FACT II system been triggered To check this turn the ignition...

Страница 37: ...plugged into the correct socket z Check the System Features Learn Routine for the default PIN code z Has the PIN code been changed The status LED does not work z Make sure that it is plugged in See th...

Страница 38: ...Trigger BLUE Instant Trigger Empty Empty WHITE Light Flash Output WHITE Light Flash Output WHITE RED Light Flash Input RED 12V Input BLACK WHITE Domelight Supervision Output 200Ma RED WHITE Accessory...

Страница 39: ...nsor Antenna Receiver CliffNet Wizard Data Port PlainView 2 Valet 87 Starter Wire Normally Open 87A Starter Wire Normally Closed 30 Starter Wire Common BLUE LED BLUE Unlock Lock Output Empty Unless Us...

Отзывы: