39
High limit switch has tripped.
Reset the SteamChef according to
instructions found in Chapter 3 If the
condition repeats, see Note 1.
Inoperative controls.
See Note 1.
Water supply to SteamChef shut OFF.
Open water supply valves.
Control panel POWER
indicator light ON and
SteamChef does not
make steam in MANUAL
or TIMED Modes.
Door interlock switch not engaged or
has failed.
Close door completely. If problem
persists, see Note 1.
Water line strainer and/or external filter
is clogged.
Clean water supply strainer and/or
external filter system.
Gas supply valve is closed.
Open gas supply valve.
Inoperative controls or solenoid.
Reset the SteamChef according to
instructions found in Chapter 3 If the
condition repeats, see Note 1.
High limit has tripped.
See Note 1.
Control panel Power
indicator is on, buzzer is
buzzing continuously,
and Reset indicator is lit.
Inoperative controls.
See Note 1.
Control panel Power
indicator is on, buzzer is
buzzing continuously.
Burner has failed to light.
Reset the SteamChef according to
instructions found in Chapter 3,
”Lighting Instructions”. See Note 1.
Compartment bottom
dirty with food drippings.
Juices and/or food leaking from pans
during loading and unloading of the
SteamChef.
Put a solid pan under perforated pans
to catch drippings.
Put less food in pan.
KleanShield
not installed.
Install KleanShield
to catch food
drippings.
Abnormal amount of
steam coming from drain
during draining of
SteamChef
ON/OFF lever not all the way OFF.
Turn ON/OFF lever all the way OFF to
start the 3-minute drain rinse cycle.
Water line strainer and/or external filter
system clogged.
Clean water supply strainer and/or
filter system.
3-minute drain rinse timer defective.
Call for service. See Note 1.
Hot water instead of cold water
connected to reservoir fill line.
See Note 2 and 3.
Inoperative controls.
Call for service. See Note 1.
The KleanShield™ drain or the main
drain is clogged or covered.
Clear the drain opening and/or clean
the drain with NSF approved drain
cleaner and flush drain thoroughly with
fresh water.
If condition persists, see Note 1.
Steam and/or water
draining around the
compartment door.
See Warning under
Note 7.
Door gasket or door parts worn.
Call for service. See Note 1.
Hot water instead of cold water
connected to the condenser water line.
See Notes 1, 2 and 3.
Troubleshooting Guide(Continued)
PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
Steam and/or water
draining around the
compartment door.
External drain not properly sized,
installed, free air vented, and/or
pitched down.
Verify drain sized and installed
properly. See the Installation Manual
See Notes 2 and 3.
SteamChef not level.
See Note 2.