38
15) After filling stops, add 1/2 gallon of water to the reservoir. Do not overflow the reservoir.
16) Turn the ON/OFF lever OFF to start the drain cycle.
17) After the reservoir drains, set the ON/OFF lever to the ON position to refill the reservoir.
18) Close the cooking compartment door and set the timer for 20 minutes (ON/OFF Control Models:
set the control to ON.). The steamer heats to normal operating temperature.
19) After 20 minutes turn OFF ON/OFF controls and turn the ON/OFF lever to OFF.
20) The 3-minute drain cycle starts.
•
This is the final rinse of the reservoir.
21) If the reservoir drains slowly even after being descaled, turn OFF the steamer and clean the
drains with a NSF approved drain cleaner.
22) Once the scale is removed and the drain flows freely, the steamer is ready for normal operation.
B. Troubleshooting Guide
The Troubleshooting Guide is a list of symptoms of problems that may be encountered during operation.
•
“Problem” (left column) lists common operating problems.
•
“Possible Cause” (center column) lists causes of problems in order they should be checked.
•
“Remedy / Reference” (right column) lists fixes for problems from easiest to hardest.
•
“Notes” in “Remedy / Reference column are at end of Table 3-1 Troubleshooting Guide.
ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING AN AUTHORIZED SERVICE
REPRESENTATIVE VOIDS WARRANTY
Table 3-1 Troubleshooting Guide
PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
Power indicator light
does not turn ON when
ON/OFF lever is in the
ON position.
Power turned OFF at main external
power switch.
Turn ON power at main external power
switch.
ON/OFF lever not fully turned to the
ON position.
Turn lever to the ON position.
Inoperative controls or indicators.
See Note 1
Power ON and
SteamChef does not fill
Water supply to SteamChef shut OFF
Open water supply lines.
Water line strainer and/or external filter
system clogged.
Clean water supply strainer and/or
filter system. See Yearly Maintenance
in Chapter 7
Gas Supply is turned OFF.
Turn gas supply ON.
Water sensor is grounded by detergent
film, or scale.
Rinse water sensor assembly
thoroughly with vinegar solution, as
described in Chapter 6, Shutdown and
Cleaning Procedure.
Inoperative controls or solenoids.
See Notes 1 and 5
Troubleshooting Guide(Continued)
PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
Control panel power
indicator light ON, and
SteamChef does not
come up to cooking
temperature or produce
steam.
Door interlock switch not engaged.
Close door completely.
Water supply to SteamChef shut OFF
Open water supply lines.
Water line strainer and/or external filter
system clogged.
Clean water supply strainer and/or
filter system. See Yearly Maintenance
in Chapter 7.
SteamChef is in the Timed Mode and
Timer is not set. (Dial Timer control
models only.)
Change to Manual Mode or set the
Timer.
Содержание SteamChef 22CGT3.1