29
f) If the burner does NOT light, reset the system:
Note: For new installations, or when air in gas lines is suspected, it may be necessary to
bleed excess air from lines. Bleed air as close as possible to the inlet of the automatic
gas valve.
(1) Turn the ON/OFF LEVER/SWITCH to OFF.
(2) Wait 5 minutes.
(3) Turn the ON/OFF LEVER/SWITCH to ON to restart the SteamChef.
(4) Repeat up to 3 times (total of 4 attempts to light the burners).
•
If the burner lights in one to four attempts, go to
g)
.
•
If the burner does NOT light after four attempts, go to
Step 7)
.
g) If the burner lights: Turn ON, the cooking compartment by:
•
EITHER Selecting Manual Mode
•
OR Setting the Timer for 10 minutes
The cooking compartment temperature rises to operating temperature.
h)
IF
the burner lights and the SteamChef heats properly within four attempts, end this test
here. Skip 7) and go to Section C. “Operating Tests and Final Checkout Procedure.”
OR
If the SteamChef does NOT light or heat properly, go to
Step 7)
.
7) If the burner does NOT light or the SteamChef does not heat properly after the fourth attempt:
•
Follow the Shutdown Instructions (below).
•
Call a qualified Cleveland Range authorized service representative to adjust the
burner controls.
2. Shutdown Instructions
1) Turn OFF the electrical power to the SteamChef at the ON/OFF lever.
2) Wait for the 3-minute Drain Rinse Cycle to run.
3) Turn OFF the Main External Power Switch.
4) Turn OFF the Main Manual Gas Valve.
Содержание SteamChef 22CGT3.1