5
Figure 3-2
Cooking Compartment
Air Diverter
Fan
Fan
Guard
D. Power ON (Automatic Water Fill / Automatic Preheat)
1. Set the TIMED/MANUAL switch to timed (Dial Timer
SteamChefs))
2. Turn ON power to the SteamChef by turning the Drain Valve
Lever clockwise (down) to close the drain. See Figure 3-3.
3. The power ON indicator lights and the SteamChef reservoir fills.
4. Close the door. The SteamChef fills to the minimum
operating level and the burner ignites.
E. Lighting and Shutdown Instructions (Normal Operation)
1.
Lighting and Shutdown Instructions for Normal Operation
DO NOT TRY TO LIGHT BURNERS WITH A FLAME.
The SteamChef has an electronic ignition system, which automatically lights burners,
senses the flame, and controls gas flow. This provides precise burner control, safe
ignition, and safe shutdown.
DEATH, INJURY, OR EQUIPMENT DAMAGE
may result from trying to light burners with
a flame or from an improperly adjusted gas control and ignition system. Do not try to light
burners with a flame. Do not alter any gas control adjustments.
If adjustment is required, contact a Cleveland Range authorized service center.
Cleveland Range is in no way responsible for the operation or safety of this equipment if
the controller, valve, igniter probe or any other gas system component is adjusted by
anyone other than a qualified Cleveland Range authorized service representative
KleanShield™ to
Drain Fit-up
Slide Rack
on Hangers
Water Probes
Door
Figure 3-3
Drain Valve Lever
Содержание SteamChef 22CGT3.1