Page 9
(3) Check equipment.
Check all safety and breathing equipment used in conjunction with the
respirator, as recommended by the manufacturer.
(4) Check air supply hose.
Check air supply hoses and connections for tightness and leaks.
(5) Put the respirator on.
Put the hood on.
Put the respirator on (keep it as upright as possible to prevent abrasive
from falling inside).
Position the knit cuff on the inner collar so that it fits comfortably. The col-
lar assists in the prevention of dust entering the helmet. Do not allow shirt
collars or other matter to interfere with the fit the cuff provides around the
user’s neck.
Pull the cape down to fully extend it, and connect the straps on each side
under the arms.
Put the belt and control valve on over the cape, Buckle the belt around the
waist and tighten it using the adjusting slide.
7 Adjustments
7.1 Control Valve
(part. no.: 100074)
Picture 1: C
ontrol valve
Clemcos Air Control Valve allows the user to increase or decrease the volume of breathing air while wear-
ing the supplied air respirator. To regulate it the button on the side has to be turned.
If connected properly to the air supply the valve allows a regulation of breathing air in a range of 130l/min
to 400l/min.
CLOSE
OPEN