  The other end of the air supply hose attach to the Air Filter CPF - 20 

respective CPF - 80 (more than one blaster). 

Use moulded-in  handle to  carry  the  respirator.  Never  hold,  carry  or 

hang the respirator by the breathing hose! 

Mishandling the respirator in this manner may damage the hose!

 

5  Air Supply 

Air  supply to this respirator system  is a  critical component for the  safety  of the user  and is not 

included in this delivery. Read this section carefully. Poor quality air will cause serious respiratory 

injury or death to the user (see 2.2). 

5.1  Air Quality 

The compressed breath air has to be conform to EN 12021. 

A supply pressure between 6-8 bars has to be assured. The supply pressure can be regulated over our 

CPF 20 filter with integrated pressure regulator (p/n 03580D) so that the blaster is provided with the right 

air quantity. 

The quality of air supplied to the respirator is extremely critical to the safety of the user. Special care must 

also be taken to avoid accidental connection to any other gas lines, such as oxygen, acetylene or nitrogen. 

Never connect a breathing air line to an air source that has not been tested for gas and particulate 

contamination

.  

Do not use piston type (oil bath) compressors for breathing air. These compressors may produce 

dangerous levels of carbon monoxide. 

The presence of unacceptable levels of carbon monoxide (CO) or other gases in the breathing air 

can cause death to the user. 

Breathing air must be only used in following conditions: 

Prior to using the respirator, read the owner

’s manual and all instructions, labels, and warnings related 

to the compressed air source. Take special care about all the statements and warnings from the com-

pressor producer. 

Warning:

 There could appear a negative pressure in the blast hood during inhala-

tion caused by a high intensity of labour. 

That is why the air control valve should be opened wider while a high intensity of labour in order 

to avoid the infiltration of dust in the blast hood. 

We recommend our carbon monoxide monitor, CMS-3 for controlling the concentration of carbon monox-

ide. 

  Regardless  to  the  air  compressor  type, precautions  must  be  taken  to  prevent  contaminants  from 

entering through the compressor intake. The compressor inlet must be located away from all sources 

of toxic contaminants including carbon monoxide which is found in engine exhaust and in any form 

of combustion. No vehicles should be allowed near the compressor intake. 

Содержание Apollo 600 CE

Страница 1: ...International GmbH Carl Zeiss Stra e 21 Tel 49 0 8062 90080 83052 Bruckm hl Mail info clemco de Germany Web www clemco international com O W N E R S M A N U A L RESPIRATOR MODEL APOLLO 600 CE CLEMCO...

Страница 2: ...ATION 8 7 ADJUSTMENTS 9 7 1 Control Valve part no 100074 9 7 2 Adjustment of Suspension 10 8 MAINTENANCE PROGRAM REPLACEMENT PARTS 10 8 1 Replacing Inner Lens 11 8 2 Replacing Outer Lens and Perforate...

Страница 3: ...5 Collar 14 9 6 Sweatband Suspension 14 9 7 Helmet Assembly 14 9 8 Lenses 14 10 STORAGE 14 10 1 Daily Storage 14 10 2 Long Duration Storage 14 11 SPARE PARTS 14 11 1 Helmet 14 11 2 Air Control Valve...

Страница 4: ...ns and limitations 2 1 General Description The Apollo 600 CE was specially developed and approved for blasting MSHA NIOSH and EN 271 The following Cautions and Limitations have to be followed The supp...

Страница 5: ...Page 5 In the moment of highest breathing air requirement during the highest work rate a sub pressure in the helmet can appear...

Страница 6: ...materials The blasthood Apollo 600CE can be used in any combination with operator safety clothing Typ 3 according to EN ISO 14877 2002 D without any restriction in an ambient with such toxics 2 3 Ear...

Страница 7: ...t been tested for gas and particulate contamination Do not use piston type oil bath compressors for breathing air These compressors may produce dangerous levels of carbon monoxide The presence of unac...

Страница 8: ...re that the volume indicator is on function which means that the flag is pulled in otherwise the flag falls down As supply hoses between the air filter and the control valve you may use only CE approv...

Страница 9: ...low shirt collars or other matter to interfere with the fit the cuff provides around the user s neck Pull the cape down to fully extend it and connect the straps on each side under the arms Put the be...

Страница 10: ...length by moving the buckle 4 Reattach cape See 8 4 The suspension maintains a fixed distance between the head and the helmet The suspension must be properly installed and adjusted to provide the prot...

Страница 11: ...ver Lenses Up to five cover lenses may be installed at one time For maximum visibility we recommend to install only so many lenses to last during a work period Preparing lenses in the following manner...

Страница 12: ...f the suspension 8 4 Cape When the cape becomes soiled or requires replacement it can easily be removed as follows 1 Detach cape Open buckle by pressing the small lever and pull out belt Remove cape 2...

Страница 13: ...nstrap look to it that the bevelled side shows to the centre of the helmet 9 Service Maintenance and Cleaning Follow washing instructions described in this section Do not use any caustic chemicals or...

Страница 14: ...any liability 9 8 Lenses Inner and outer lenses should be replaced when pitted or scratched However mild detergent and water can be used to clean them Volatile solutions such as alcohol gasoline or am...

Страница 15: ...uspension A 600 2J1 23821 I Clip A 600 head suspension 4 units head suspension necessarily 2L 23801 D A 600 cape attachment Pos Part No Model 2L3 23803 D A 600 draw latch window frame 2L4 24245 D Scre...

Страница 16: ...mm air hose 54 01030 D Hose connection 55 100042 Air control valve complete with belt 56 100421 5m Air Supply Hose 9mm with safety coupling and socket CE approved 100406 10m Air Supply Hose 9mm with s...

Страница 17: ...Page 17 Picture 4 Single components of Apollo 600 CE A Nylon cape for A 600 p n 23815D B Leather cape for A 600 p n 24310D...

Страница 18: ...r A 600 p n 24405D D ASS Cape 4436 RA for A 600 p n 24406D Picture 5 A D CE certificated Capes for Apollo 600 11 4 Additional parts Options Clem Cool air conditioner 23825D Climate control 04411I DLX...

Отзывы: