18
YOURx-Aerial Terminal
Installation Manual
_________________________________________________________
Manual 019588 REV B - Sept 2018
Splicing in the YOURx-Aerial Terminal
Splice Tray Setup
Splice trays (P/N 019339) will be shipped with 2 standard splice chips and 2 ribbon splice chips, allowing for a total of 24
loose tube splices or 6 ribbon mass fusion splices (72 fibers). Splice chips will need to be gently bent, placing both ends into
the empty slots in the center of the splice tray.
Note:
Each standard splice chip features 6x2 splice sleeve slots, allowing for 12 splice sleeves to be stacked 2 high in the
6 slots. Each ribbon splice chip features 3 ribbons splice sleeve slots, as well as one 2 high loose tube splice sleeve slot for
use in special applications or repairs.
Splice Chip
Ribbon Splice Chip
Bending the Splice Chip
Splice Tray Loaded with
2 Splice Chips
Splice Tray Loaded with
2 Ribbon Splice Chips