Manual 019588 REV B - Sept 2018
Step 3
:
Pass breakout 3mm cable
through FlexConnector.
Step 1:
Prep cable to YOURx length
(14 inches) cutting strength members
flush with black, outer cable
sheath.
Installing the Field Installable FlexConnector
Step 4
:
Stop short of cable sheath.
Step 6
:
Attach clips to top and bottom of cable, teeth
in, even at cable sheath opening. A groove on the clip
allows for proper alignment.
Step 5
:
Align nose of clips to end of
black cable and sandwich together.
Nose
Teeth
(1) 3/4” x 2 1/4” long (004867)
(1) 1/2” x 2 1/4” long (004644)
(1) 5/16” x 3” long (004458)
Step 2
:
For water tight seal, feed the following three
lengths of heat shrink onto cable for later use: