17
YOURx-Aerial Terminal
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 019588 REV B - Sept 2018
Step 7:
Once all cables are loaded into terminal, place the end plates on each side of terminal. Placing the ribbed side of
plate to the inside, press the end plate until it locks into place, ensuring the top and bottom 1/2 grommets are located in all 4
cable entrance locations.
Step 8:
From the newly installed cable bundle, remove the buffer tube/ribbons that will be spliced in the splice tray and set
them aside. Store the remaining buffer tubes/ribbons in the slack management basket (buffer tubes) or rings (ribbon).
Buffer Tube
Ribbon
Step 9:
Store 2-3 wraps of the buffer tubes/ribbons you intend to splice, slack that will be used to bring the splice tray and
fibers to your workspace and perform the splices.
Step 10:
Clearfield recommends an additional 3ft/1m of fiber after the 2-3 slack wraps, which will be used for splicing in the
splice tray.
Step 11:
Remove the slack wraps of the ribbons/buffer tubes you intend to splice.