26
FieldSmart
®
FxMP Panel & Standard Frame
Installation Manual
_________________________________________________________
Manual 019807 REV A - June 2018
Start with the buffer tubes that correspond to the
cassettes on the same side of the panel that the
cable is mounted. Bring the buffer tubes over to
the other side of the panel and drop down into
the slack basket, then start to coil them in the
basket.
Note:
If the cable is mounted to the left side of
the panel as shown in these images, start with
the buffer tubes that enter the cassettes on the
left side of the panel (when looking from the
back).
After both sides of the panel’s cassettes have
been spliced and installed into the panel, it is
time to store the buffer tube slack in the slack
basket. Make use of the bridge lances/tie-down
locations during installation to secure the buffer
tubes with the provided velcro.
8.
9.
Since the buffer tubes will be routing in the
opposite direction that is needed for a clean
sweep up to the cassettes, a redirect to the
direction of the coil will need to be added. Cut
through the middle of the slack basket and
curve back up, beginning to coil in the opposite
direction.
10.