Once you’ve mounted the panel and the cable is attached to the frame, open up your cable. Clearfield recommends a
cable opening of 11 feet (up to 8ft of slack (depending upon panel size) and 3ft for splicing in the cassette). Proceed to
mounting the cable to the panel.
Use the included mounting screws to fasten the cable clamps and
cable to the rear cable bracket. The cable should be mounted so
that the breakout is slightly beyond the end of the clamp.
Note:
Panels shown in images may not match product received.
Cable mounting will be performed in the same manner regardless.
Clamp the cable to the panel using the same method you used
to mount it to the frame, choosing the closest size pair of cable
clamps, and using grommet tape to make up the size difference.
If mounting the cable to the back of
a 1RU panel, a vinyl coated P-clip
(supplied as a ship-along) will need
to be used to secure the cable. Use
grommet tape around the cable as
needed to increase the size of the
cable for proper grip.
7.
8.
9.
10.