Intended use

GP - Series | Version 1.03

7

2.6 Safety labels on the water pump

The following safety labels and instructions are attached 
to the water pump (Fig. 1) and must be ob-served.. 

Fig. 1:  Safety labels

If safety labels on the machine are damaged or missing, 
this can cause errors, personal injury and material dam-
age. The safety symbols attached to the machine must 
not be removed. Damaged safety symbols must be re-
placed immediately.

As soon as the signs are not clearly visible and compre-
hensible at first glance, the machine must be stopped 
until new signs have been attached.  

3

Intended use

The water pump is used exclusively for water supply in the 
domestic area such. Irrigation of the garden, as well as for 
pressurization and general water movement in the house

-

hold.

The water pump must not be operated in potentially explo

-

sive environments and the max. permissible temperature of 
the pumped medium must not exceed 35 ° C.

Proper use also includes compliance with all information in 
this manual.

For structural and technical changes to the water pump, the 
company Stürmer Maschinen GmbH assumes no liability.

Claims of any kind due to damage due to improper use are 
excluded.

3.1 Improper use

3.2 Residual risks

Even if all safety instructions are observed, and the ma-
chine is put to its intended use, there are still residual 
risks, which are listed below:

-  Risk of injury of upper and lower limbs while equip-

ment is operating.

-  Heat build-up on components can cause burns and 

other injuries.

-  Danger of fire and explosions in connection with the 

absorption of wrong liquids.

-  Electrical hazards due to contact with parts and high 

voltage (direct contact) or with parts that are under 
high voltage due to a defect in the device (indirect con

-

tact).

ATTENTION!

Any change on the water pump is prohibited. The 
change may void the warranty, cause burns and per

-

sonal injury, even fatal for the user.    
The manufacturer will not be liable for any damage 
that the results from failure to follow these instructi-
ons or from the misuse of the equipment to objects or 
persons. 

WARNING!

Danger in case of misuse!

Misuse of the water pump can lead to dangerous sit-
uations.  
-  Only operate the water pump in the power range li

-

sted in the technical data.

-  Never bypass or override the safety devices.

-  Only operate the water pump in a technically per-

fect condition.

ATTENTION!

The pump is not suitable for pumping salt water, fae-
ces, flammable, corrosive, explosive or other dan-
gerous liquids. 
The delivery fluid must not exceed or fall short of the 
maximum or minimum temperature specified in the 
technical data. 

-  Do not soak up aggressive cleaning agents as they 

could damage the device.

-  do not absorb any materials that may damage the fil

-

ter elements (e.g., broken glass, metal, etc.).

Содержание 7521100

Страница 1: ...W ATER P UMP Garden Pump GP 1105 S Operating Instructions GP 1105 C GP 1105 S GP 1105 P GP 1306 S GP 1105 P GP 1306 S GP 1105 C...

Страница 2: ...rating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual...

Страница 3: ...dge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructi...

Страница 4: ...correspond to the current status of the regulations and must ad apt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation...

Страница 5: ...o protect per sons against impairments of safety and health while wor king The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which ar...

Страница 6: ...ot used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a clos...

Страница 7: ...ne is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns an...

Страница 8: ...8 m 8 m Engine speed 2850 min 2850 min Engine power 1100 W 1100 W Cooling Air cooling Air cooling Sound pressure level 82 dB 84 dB Running time at 75 load 4000 Std 4000 Std Length of cable 1 5 m 1 5...

Страница 9: ...ms may be parked on it Step 1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and s...

Страница 10: ...ording to the current water level in the water tank Display functions GP 1105 S Fig 7 Display functions GP 1105 S The water pump GP 1105 S has a LCD display with two buttons SET and CHECK which makes...

Страница 11: ...can cause damage When laying the connecting cables make sure that no weight vibrations or tensions are applied to the pump In addition the connecting cables must not be damaged or have a counterfall t...

Страница 12: ...ne person Other persons must keep away from the water pump during operation ATTENTION Make sure that only fresh water is pumped with the water pump Using the water pump for other fluids will damage th...

Страница 13: ...that are not resistant to internal pressure may cause the pres sure line to burst during operation This may cause injury due to liquid escaping from the line DANGER Danger to life due to electric shoc...

Страница 14: ...d with water If this venting is omitted the pump does not suck in the pumped liquid It is recom mended but not necessary in addition to deaerate the suction line or to fill it with water ATTENTION Dry...

Страница 15: ...ce For any trans port the pump must be disconnected from the mains The pump must be completely emptied and stored in a frost proof condition Only a regularly maintained and well maintained device can...

Страница 16: ...are available from the manufacturer of the lubricants If necessary request the product specific data sheets 13 Disturbances possible causes and measures ATTENTION If one of the following errors occurs...

Страница 17: ...nozzle in take manifold suction hose or filter 1 Remove blockages 2 Clean or change the filter 3 Insert the filter cover correctly 4 Check correct installation position of the filter Pump is not runni...

Страница 18: ...an for the water pump GP 1105 C must be ordered The fan wheel has the number 35 in the spare part dra wing Type of device Garden pump GP 1105 C Item number 7521100 Position number 35 The order number...

Страница 19: ...re Parts Drawing GP 1105 C In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to you...

Страница 20: ...20 GP Series Version 1 03 Spare Parts 14 3 Spare Parts Drawing GP 1105 P Fig 11 Spare Parts Drawing GP 1105 P 14 4 Spare Parts Drawing GP 1105 S Fig 12 Spare Parts Drawing GP 1105 S...

Страница 21: ...Spare Parts GP Series Version 1 03 21 14 5 Spare Parts Drawing GP 1306 S Fig 13 Spare Parts Drawing GP 1306 S...

Страница 22: ...22 GP Series Version 1 03 Wiring Diagrams 15 Wiring Diagrams GP 1105 S Fig 14 Wiring Diagram GP 1105 S GP 1306 S 1105 P und 1105 C Fig 15 Wiring Diagram GP 1306 S 1105 P and 1105 C...

Страница 23: ...DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 Household and similar electrical appliances Safety Part 2 41 Particular requirement...

Страница 24: ...www cleancraft de...

Отзывы: