10
GP - Series | Version 1.03
Device description
Garden pump GP 1306 S
Fig. 6: Description GP 1306 S
1 Drainage connection
2 Carrying handle
3 ON / OFF switch
4 Water drain plug
5 Suction connection
6 Water filler neck
7.1 Operation and function
Operation
The house water system can be used for household wa-
ter supply, equipment support, well water lifting, pipe-line
pressurization, garden watering, vegetable green-house
watering, fish farming and poultry raising, etc.. Transfer
clean water and other noncorrosive liquids with low vis
-
cosity; do not transport inflammable, explosive, gasified
liquids and liquids containing solid parti-les or fibers. The
PH of water must between 6.5 and 8.5.
Function
This pump series can be converted into an automatic
water pump, which consists of an external automatic
system with a pressure switch, a pressure tank, etc.
The features of the automatic pump are as follows:
Once the pump is on, turn on the water supply and the
pump will start working automatically. When you turn off
the water supply, the pump stops automatically.When
using a water tank together with the automatic pump,
you can fill the tank and the pump stops according to the
current water level in the water tank.
.
Display functions GP 1105 S
Fig. 7: Display functions GP 1105 S
The water pump GP 1105 S has a LCD display with two
buttons "SET" and "CHECK" which makes it possible to
make adjustments to the pump.
Turn the water pump on and off:
After the plug of the water pump is plugged in, the pump
indicates "OFF". After 3 seconds the pump switches on
and the display shows "pressure" or "flow".
To switch between "Pressure" or "Flow", press the
"CHECK" key while the pump is running.
To switch off the garden pump, briefly press the "SET"
button.
Set the water pressure:
To set the pressure, press the "SET" button. To increase
the pressure, briefly press the "SET" button and to de-
crease the pressure, briefly press the "CHECK" button.
After setting the water pressure, exit the setting menu by
pressing and holding the "SET" button
Dry runnig safety:
When the water pump started and no flow is detected
within 100 seconds, the pump stops for 5 seconds. Then
the pump start 2 more cycles to detect a flow. If no flow is
detected within these 2 cycles, the pump swit-ches off
and the display shows "ERROR". To switch the pump on
again, the plug must be disconnected from the mains
and plugged in again.
1
2
5
4
3
6
ATTENTION!
Make sure that the water tank of the pump is always
filled with water before starting the pump. Dry run-
ning may damage the pump.