9.1 Connection of the suction pipe

Fig. 9:  Connection of the suction pipe GP 1105 C

1  Drain plug

2  Water pump

3  Wasser tap

4  Pressure pipe

5  Filling plug

6  Fitting

7  Inlet pipe

8  Valve

ATTENTION!

Only use an extension cable whose cross-section 
and rubber sheathing correspond at least to the 
connection cable of the device and are marked with 
the corresponding abbreviation according to VDE.
Power plugs and couplings must be splash-proof. 

WARNING!

Danger to life!

There is danger to your life if you do not follow these 
rules.
-  Never work with the water pump if you are under the 

influence of alcohol, drugs or medications and / or 
you are overtired or suffer from concentration-distur

-

bing illnesses.

-  Die Submersible water pump may only be operated 

by one person. Other persons must keep away from 
the water pump during operation.

ATTENTION!

Make sure that only fresh water is pumped with the 
water pump. Using the water pump for other fluids 
will damage the pump. 

ATTENTION!

To avoid fire hazards, keep the pump at least 
1 meter away from building walls and other equip-ment 
during operation. Do not place flammable objects near 
the engine.

Wear protective cloth!

Wear safety shoes!

Wear safety glasses!

ATTENTION!

Check the general condition of the hoses. Make sure 
that the hoses are not damaged before connecting 
them to the pump. 

ATTENTION!

Before commissioning, always fill the pump with water. 
Dry running can cause damage.

ATTENTION!

The suction pipe must be installed in such a way that 
it cannot exert any mechanical forces or distor-tions 
on the pump.

ATTENTION!

When pumping dirty liquids, install a intake filter to 
protect the pump from sand and dirt.

NOTE!

It is recommended to install a non-return valve to 
prevent water backflow when the pump is switched 
off. 

Содержание 7521100

Страница 1: ...W ATER P UMP Garden Pump GP 1105 S Operating Instructions GP 1105 C GP 1105 S GP 1105 P GP 1306 S GP 1105 P GP 1306 S GP 1105 C...

Страница 2: ...rating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual...

Страница 3: ...dge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructi...

Страница 4: ...correspond to the current status of the regulations and must ad apt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation...

Страница 5: ...o protect per sons against impairments of safety and health while wor king The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which ar...

Страница 6: ...ot used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a clos...

Страница 7: ...ne is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns an...

Страница 8: ...8 m 8 m Engine speed 2850 min 2850 min Engine power 1100 W 1100 W Cooling Air cooling Air cooling Sound pressure level 82 dB 84 dB Running time at 75 load 4000 Std 4000 Std Length of cable 1 5 m 1 5...

Страница 9: ...ms may be parked on it Step 1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and s...

Страница 10: ...ording to the current water level in the water tank Display functions GP 1105 S Fig 7 Display functions GP 1105 S The water pump GP 1105 S has a LCD display with two buttons SET and CHECK which makes...

Страница 11: ...can cause damage When laying the connecting cables make sure that no weight vibrations or tensions are applied to the pump In addition the connecting cables must not be damaged or have a counterfall t...

Страница 12: ...ne person Other persons must keep away from the water pump during operation ATTENTION Make sure that only fresh water is pumped with the water pump Using the water pump for other fluids will damage th...

Страница 13: ...that are not resistant to internal pressure may cause the pres sure line to burst during operation This may cause injury due to liquid escaping from the line DANGER Danger to life due to electric shoc...

Страница 14: ...d with water If this venting is omitted the pump does not suck in the pumped liquid It is recom mended but not necessary in addition to deaerate the suction line or to fill it with water ATTENTION Dry...

Страница 15: ...ce For any trans port the pump must be disconnected from the mains The pump must be completely emptied and stored in a frost proof condition Only a regularly maintained and well maintained device can...

Страница 16: ...are available from the manufacturer of the lubricants If necessary request the product specific data sheets 13 Disturbances possible causes and measures ATTENTION If one of the following errors occurs...

Страница 17: ...nozzle in take manifold suction hose or filter 1 Remove blockages 2 Clean or change the filter 3 Insert the filter cover correctly 4 Check correct installation position of the filter Pump is not runni...

Страница 18: ...an for the water pump GP 1105 C must be ordered The fan wheel has the number 35 in the spare part dra wing Type of device Garden pump GP 1105 C Item number 7521100 Position number 35 The order number...

Страница 19: ...re Parts Drawing GP 1105 C In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to you...

Страница 20: ...20 GP Series Version 1 03 Spare Parts 14 3 Spare Parts Drawing GP 1105 P Fig 11 Spare Parts Drawing GP 1105 P 14 4 Spare Parts Drawing GP 1105 S Fig 12 Spare Parts Drawing GP 1105 S...

Страница 21: ...Spare Parts GP Series Version 1 03 21 14 5 Spare Parts Drawing GP 1306 S Fig 13 Spare Parts Drawing GP 1306 S...

Страница 22: ...22 GP Series Version 1 03 Wiring Diagrams 15 Wiring Diagrams GP 1105 S Fig 14 Wiring Diagram GP 1105 S GP 1306 S 1105 P und 1105 C Fig 15 Wiring Diagram GP 1306 S 1105 P and 1105 C...

Страница 23: ...DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 Household and similar electrical appliances Safety Part 2 41 Particular requirement...

Страница 24: ...www cleancraft de...

Отзывы: