15
on-hand to minimize downtime should a component wear out or break.
1 additional Pin Set
Assembly
1 additional
Magazine
1 additional Jaw
Set
6.0 Product Specifications
Unit Weight
44 LBS / 19.95 KG
Overall Dimensions
23.75 in. (60.32cm) lg. x 9.125 in.
(23.17cm) w. x 10.25 in. (26.03cm) ht.
Minimum/Maximum PSI
100 PSI /120 PSI
AC Power Supply
110-120 VAC, 50-60 Hz, 3A
7.0 Trouble Shooting
Operating Error
Action
Unit does not operate.
1.
Check the facility air connection.
2.
Check both regulators are set to the proper
Pressure (Section 2.2
Air Supply)
3
. Check electrical power, 110VAC & 24 VDC
4
. Check all safeties:
Cover switch-make sure cover is
completely on
Magazine switch-make sure magazine
is pushed down all the way in the
magazine rack
Last fitting sensor- verify last fitting is
in position (Section 2.6
Magazine
Installation)
Tubing does not go on the fitting / all the way on.
1.
Adjust Stop Gate position (Section 2.5
Adjust
the Stop Gate
)
2
. Adjust high pressure, should be 80-120 psi.
8.0 Durometer Scale