14
Once the Last Fitting Sensor is adjusted properly, it will remain lit with four (4) pieces of paper (Figure
9.1) and turn off with five (5) pieces of paper (Figure 9.4).
100.75
Operation
3.1 Loading Magazine and Jaws
Hook up the air FIRST and then turn on the power
Fill the magazine with fittings (5 minimum)
Insert a tube into the jaws, pushing forward until gate switch is hit.
Unit will cycle pushing the fitting into tube and then dropping the assembly down
3.2 Fitting Sensor Lamp
Yellow lamp is always on when machine is operating. If lamp is out it indicates that
the magazine is empty of fittings or the fitting is not all the way down in the proper
position in the magazine.
100.75
Maintenance
4.1 Daily
Once each day:
the pin set should be retightened onto the air
cylinder. Loose pin sets can result in damage to the unit.
Once each day:
ensure that the screws holding the jaws on are tight.
Loose screws will allow the jaws to move enough that fittings may
not properly insert into the tubing.
Once each day:
disconnect the air at the rear of the unit and pull the
pin set toward the magazine hole and be sure that it enters the hole
freely (without hanging up on the side-wall). The pin set must enter
the magazine hole without moving the magazine or damage can
occur.
4.2 Every three months
Once every three months
, the lid should be opened and the inside
around the jaw set and magazine should be cleaned via air (no more
than 30psi). This will remove any dust that has collected. At this time,
air connectors on the manifold should be checked for tightness. The
pin-set should be checked to make sure it is tight. Any dust or debris
which the blown air did not clean up should be wiped away.
5.0 Recommended Spare Parts
It is strongly recommended that you keep at least the following components