![CLEAN BURN CB-1400 Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/clean-burn/cb-1400/cb-1400_operators-manual_2619992081.webp)
Operator's Manual: Model CB-1400
9-7
Figure 9E - Accessing the Combustion Chamber for Cleaning
Cleaning Ash from the Furnace (continued)
1.
Ensure that power has been turned OFF, and all "hot" components have been allowed to cool
sufficiently. Allow at least one hour for the target to cool.
2.
Clean out the burner throat:
a. Disconnect the burner power cable.
b. Remove the lock-down nut and swing the burner open.
c. Clean out the burner throat using a small scraper to remove the residues.
ATTENTION:
Keep the burner open (swung out) so that you do not knock or bend burner
components when cleaning out the combustion chamber.
3.
Clean the ash from the stack components:
a. Brush accumulated ash from the stack cap.
b. Lightly tap the stack components to loosen the ash.
c. Allow ash and dust to settle in the clean-out tee or elbow.
d. Vacuum ash from the clean-out tee, or disconnect the stack and vacuum ash from the elbow.
Содержание CB-1400
Страница 2: ......
Страница 8: ......
Страница 15: ...Operator sManual ModelCB 1400 1 7 For Your Safety continued CB 1400 Furnace Cabinet Safety Labels ...
Страница 18: ...Operator sManual ModelCB 1400 1 10 ...
Страница 62: ...Operator sManual ModelCB 1400 5 8 ...
Страница 68: ...Operator sManual ModelCB 1400 7 2 ...
Страница 84: ...Operator sManual ModelCB 1400 9 10 ...
Страница 92: ...Operator sManual ModelCB 1400 10 8 ...
Страница 106: ...Operator sManual ModelCB 1400 B 4 Wiring Diagrams continued FigureB4 MeteringPumpWiringSchematic H44040 ...
Страница 108: ...Operator sManual ModelCB 1400 C 2 ...