Operator's Manual: Model CB-1400
9-3
Cleaning the Canister Filter
ATTENTION:
Never operate your furnace with more than 10" HG of vacuum on the suction side of
the pump. High vacuum separates air from the oil and results in erratic burner operation.
The following protective gear should be worn when cleaning the filter:
•
Rubber gloves
•
Safety goggles
1.
Close the ball valve adjacent to the filter.
2.
Position a container under the filter.
3.
Unscrew the four bolts to drain the oil from the canister.
4.
Remove the canister bowl.
5.
Clean the screen and the bowl in a parts washer.
6.
Referring to Figure 9B, examine the filter components as you reassemble them.
7.
Check the condition of the O-rings. Replace any that are cracked or worn.
8.
Ensure that the canister filter is 100% airtight by firmly tightening the four bolts.
9.
After the pump head screen is serviced as well (page 9-4) open the ball valve and refer to Sections
5 and 6 for instructions on priming the pump and starting the burner.
Figure 9B - Canister Filter Component Detail
TO BURNER
BACK TO
TANK
I88259−A
USE A RATCHET WRENCH WITH A 6" EXTENSION
AND 3/16" "ALLEN" SOCKET TO REMOVE THE
FOUR "ALLEN" SCREWS
Содержание CB-1400
Страница 2: ......
Страница 8: ......
Страница 15: ...Operator sManual ModelCB 1400 1 7 For Your Safety continued CB 1400 Furnace Cabinet Safety Labels ...
Страница 18: ...Operator sManual ModelCB 1400 1 10 ...
Страница 62: ...Operator sManual ModelCB 1400 5 8 ...
Страница 68: ...Operator sManual ModelCB 1400 7 2 ...
Страница 84: ...Operator sManual ModelCB 1400 9 10 ...
Страница 92: ...Operator sManual ModelCB 1400 10 8 ...
Страница 106: ...Operator sManual ModelCB 1400 B 4 Wiring Diagrams continued FigureB4 MeteringPumpWiringSchematic H44040 ...
Страница 108: ...Operator sManual ModelCB 1400 C 2 ...