Operator's Manual: Model CB-1400
3-8
Locking the Burner into Firing Position
1.
Swing the burner into firing position.
2.
Install and tighten the lock-down nut on the mounting
plate bolt to secure the burner in its firing position.
3.
Plug the burner electrical cable into the receptacle on the
top of the burner housing.
4.
Tighten the locking ring to secure the electrical cable.
NOTE:
Be sure to properly align the plug when plugging it into
the receptacle. See Fig 3I.
CONNECTOR PLUG
KEY IN PLUG
MUST ALIGN
WITH SLOT IN
RECEPTACLE
RECEPTACLE ON
TOP OF BURNER
I88641−B
Figure 3I - Detail of Burner
Electric Receptacle
Figure 3H - Installation of Connector Block, Oil Line, and Air Line (Front View)
Installing the Connector Block, Oil Line Tubing, and Air Line Tubing
(continued)
AIR OIL
CONNECTOR BLOCK INSTALLED
ON FURNACE CABINET
COMPRESSION/
SWIVEL FITTING
OIL LINE
AIR LINE
OIL LINE FITTING
ON BURNER
AIR LINE FITTING
ON BURNER
Содержание CB-1400
Страница 2: ......
Страница 8: ......
Страница 15: ...Operator sManual ModelCB 1400 1 7 For Your Safety continued CB 1400 Furnace Cabinet Safety Labels ...
Страница 18: ...Operator sManual ModelCB 1400 1 10 ...
Страница 62: ...Operator sManual ModelCB 1400 5 8 ...
Страница 68: ...Operator sManual ModelCB 1400 7 2 ...
Страница 84: ...Operator sManual ModelCB 1400 9 10 ...
Страница 92: ...Operator sManual ModelCB 1400 10 8 ...
Страница 106: ...Operator sManual ModelCB 1400 B 4 Wiring Diagrams continued FigureB4 MeteringPumpWiringSchematic H44040 ...
Страница 108: ...Operator sManual ModelCB 1400 C 2 ...