background image

ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through
an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

WARNING! THIS APPLIANCE MUST BE EARTHED

IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:

Green & Yellow

-

Earth

 Blue

-

Neutral

Brown

-

Live

As the colours of the flexible lead of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:

Connect GREEN & YELLOW cord to terminal marked with a letter “E” or Earth
symbol “    ” or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter “L” or coloured RED.

Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK.

If this appliance is fitted with a plug which is moulded onto the electric cable
(i.e. non-rewireable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most
electrical stockists

FUSE RATING

The fuse in the plug must be replaced with one of the same rating (13 amps) and
this replacement must be approved to BS1362.

We recommend that this machine is connected to the mains supply via a Residual
Current Device (RCD)

If in any doubt, DO NOT attempt any connections or repairs yourself. Consult a
qualified electrician, your Clarke dealer, or CLARKE International Service Dep’t
on

020 8988 7400 or e-mail: Service@clarkeinternational corn

5

Содержание WIZ - MINI

Страница 1: ...WIZ MINI AIR COMPRESSOR OPERATING MAINTENANCE INSTRUCTIONS 0206...

Страница 2: ...achieve long and trouble free service from your compressor GUARANTEE This product is guaranteed against faults in manufacture for 12 months from pur chase date Please keep your receipt as proof of pu...

Страница 3: ...t paint manufacturers instructions for safety and usage 9 Do not exert any strain on electrical cables and ensure that air hoses are not tangled or wrapped around machinery etc 10 Before disconnecting...

Страница 4: ...with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is sub...

Страница 5: ...ays use this switch to shut down the compressor NEVER USE THE MAINS SWITCH TO STOP MOTOR 2 Trigger the equipment spray gun air tool etc to release air from the air hose before disconnecting the hose f...

Страница 6: ...Air Hose Back off all screws and tighten equally to 10 lbf ft Consult your Clarke dealer Back off all screws and tighten equally to 10 lbf ft Consult your Clarke dealer Consult your Clarke dealer Swit...

Страница 7: ...PARTS DIAGRAM 8...

Страница 8: ...sher KLWIZ45 14 Screw KLWIZ14 46 Nut KLWIZ46 15 Washer KLWIZ15 47 Bearing KLWIZ47 16 Screw KLWIZ16 48 Rear Body Cover KLWIZ48 17 Plate w Con Rod KLWIZ17 49 Washer KLWIZ49 18 Washer KLWIZ18 50 Screw KL...

Отзывы: