5.8.2   SWING DOOR RE-ARMING 

INSTRUCTION

   

ENSURE THAT YOU HAVE THE PROPER CLIP  

TYPE FOR YOUR SIZE VENT. FAILURE TO USE  

THE CORRECT CLIPS MAY CAUSE VENT TO 

FUNCTION IMPROPERLY.

in the event of an explosion or other unforeseen 

circumstances, it may be necessary to re-arm the 

explosion vent located on your Dust collector. Parts 

discussed in this procedure are identified by numbers 

that coincide with those shown by a detail drawing and 

parts list.
a violent explosion may deform the doors 

(7)

 

(1)

 which 

will require replacement in addition to the clip hold 

downs 

(3)

 and flat clip supports 

(4)

.

Before re-arming a vent where doors are not 

damaged:

1.  check the flat clip supports 

(4) 

for flatness. if only 

one end is bent, flip or rotate 180°, and reuse. if both 

ends are bent, replace. Do not flatten and reuse, as 

the operating characteristics of the vent will change.

2.  reorder clip hold downs 

(3) 

and replace. Do not 

flatten or reuse clip hold downs.

3.  check gasketing. replace if damaged or abnormally 

compressed. if vent has been in operation for two 

years, replace gasket.

4.  Loosen four socket hex cap screws 

(17) 

on door 

compression plate 

(8

). remove bent clip hold  

downs 

(3)

.

5.  Loosen nuts 

(9) 

holding flat clip supports 

(2)

 on 

internal door edge 

(7)

. check flat clip supports 

(2)

 as 

directed above. rotate 90° so flat clip support 

(2)

 is 

parallel with the door edge 

(7)

.

6. Pull door 

(1)

 into an almost closed position.

7.  Pull door 

(7)

 against door 

(1)

 until both doors are 

closed and hold. Make sure that both top and bottom 

door edges fit under gasket.

8.  rotate flat clip support 

(2)

 90° so that the flat side 

is over the edge of the door 

(1)

 in a perpendicular 

position. finger tighten nuts 

(9)

.

9.  Push new clip hold downs 

(3)

 into recessed area of 

clip support block 

(18)

 until they stop. Make sure that 

the forward edge of the clip hold downs 

(3)

 are over 

the outside edge of the door plate 

(5)

.

10. tighten four socket hex cap screws 

(17)

.

11.  tighten nuts 

(9)

. Make sure the flat clip supports  

(2)

 remain perpendicular to the edge of the  

doors 

(7) (1)

.

12. release handle. explosion vent is now rearmed.

6.  TROUBLESHOOTING GUIDE

use the troubleshooting guide to correct any  

problems that occur with your dust collection unit. 

if the problem or condition continues, contact the 

uaS customer service office.

    all electrical/mechanical troubleshooting should be 

performed by a qualified electrician/maintenance 

individual familiar with uaS equipment.

    Prior to troubleshooting any equipment, read the 

installation and operation Manuals for each piece  

of equipment to be serviced.

!

 

WARNING

   CAUTION

Содержание UAS SFC Series

Страница 1: ...Downward Flow Cartridge Dust Collector l Model SFC l PATENT NO 6 902 592 OWNER S MANUAL...

Страница 2: ...when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL ________________...

Страница 3: ...ogether Module Sections applies to 4 or more modules 6 3 4 Electrical Installation 11 3 4 1 Mounting the Controls 11 3 4 2 Solenoid Valve Enclosure Wiring 11 3 4 3 Heater Wiring 15 3 5 Compressed Air...

Страница 4: ...al 24 5 3 Servicing the Compressed Air Components 25 5 4 Servicing the Direct Drive Blower and Motor System 25 5 5 Servicing Cartridge Media 25 5 6 Servicing Optional Return Air Safety Filters HEPA AS...

Страница 5: ...t collector The unit should be inspected frequently and dirt removed to prevent excessive accumulation which may result in flash over or fire damage The SFC system should not be used to support person...

Страница 6: ...r are recommended to be located outside the building in non traffic areas even though the dust collector is equipped with an explosion vent 2 INTRODUCTION Thank you for selecting UAS dust collection e...

Страница 7: ...e pulse cleaning mechanism provides brief bursts of compressed air directed through the diaphragm valves toward the cartridge filter This pulsing action dislodges the collected particles from the medi...

Страница 8: ...installation kit Hopper assemblies will be shipped in pieces and will need to be assembled at the site The hopper sections are shipped in pieces for field assembly Position the legs as shown in Figure...

Страница 9: ...4 Revised 04 15 SFC Cartridge Dust Collector FIGURE 2 SFC Typical Single Unit Installation Diagram 44 10335 0001...

Страница 10: ...5 Revised 04 15 SFC Cartridge Dust Collector FIGURE 3 Recommended Unit Clearances 44 10337 0001...

Страница 11: ...mbly is equipped with four 1 2 13mm pry locations two holes on front flange and two holes on rear flange Refer to Figure 7 Detail C to aid in aligning the hopper flange with the module flange With fil...

Страница 12: ...7 Revised 04 15 SFC Cartridge Dust Collector FIGURE 4 Single Hopper SFC 44 10309 0001...

Страница 13: ...8 Revised 04 15 SFC Cartridge Dust Collector FIGURE 5 Multiple Hopper SFC 44 10309 0002...

Страница 14: ...9 Revised 04 15 SFC Cartridge Dust Collector FIGURE 6 Multiple Hopper SFC 44 10309 0003...

Страница 15: ...10 Revised 04 15 SFC Cartridge Dust Collector FIGURE 7 Multiple Modules SFC 44 10310 0001...

Страница 16: ...itor DPM for continuous pulse cleaning Motor starter with Digital Pulse Control DPC for on demand pulse cleaning VFD with DPM for continuous pulse cleaning VFD with DPC for on demand pulse cleaning Re...

Страница 17: ...12 Revised 04 15 SFC Cartridge Dust Collector FIGURE 8 SFC Pressure Gauge Installation 44 10333 0001 Rev A...

Страница 18: ...13 Revised 04 15 SFC Cartridge Dust Collector FIGURE 9 Solenoid Wiring to Pulse Controls for 2 3 4 and 5 Tier Units...

Страница 19: ...14 Revised 04 15 SFC Cartridge Dust Collector FIGURE 10 Pneumatic Valve Assembly 44 10332 0001...

Страница 20: ...fitting sealant on all compressed air supply pipe fittings and connections 3 6 ASSEMBLY OF OPTIONAL EQUIPMENT 3 6 1 BLOWER PACKAGE INSTALLATION TIP OVER HAZARD Anchor dust collector to concrete pad pr...

Страница 21: ...6 Revised 04 15 SFC Cartridge Dust Collector Figure 11 Legs Support Top Mount Blower 44 10331 0001 NOTE FOR BLOWERS 20 HP OR LARGER SUPPORT LEGS ARE REQUIRED TO BE INSTALLED UNDER THE CLEAN AIR PLENUM...

Страница 22: ...17 Revised 04 15 SFC Cartridge Dust Collector Figure 12 Abrasive Inlet Installation 44 10338 0001...

Страница 23: ...ing parts on the rotary air lock Do not allow any object to be placed in or near the rotary air lock during operation Verify rotary air lock rotation matches rotation arrows affixed to assembly 3 6 4...

Страница 24: ...ons NOTE The hopper s is not designed for dust storage The slide gate should remain open during normal operation 3 6 6 INLET COVER AND BLANK COVER PLATE INSTALLATION Inlet collar and blank cover plate...

Страница 25: ...20 Revised 04 15 SFC Cartridge Dust Collector Figure 16 EDAP Interconnection Figure 15 EDAP Installation 48 10007...

Страница 26: ...shipping routine for an assembled SFC unit is with an enclosed box truck This type of truck will not be able to transport an assembled 4 high unit due to height restrictions within the vehicle When s...

Страница 27: ...22 Revised 04 15 SFC Cartridge Dust Collector Figure 17 SFC Series Door Filter Installation 44 10329 0001...

Страница 28: ...n 1 5 w g 25 127 mmAq At start up this reading is generally in the 1 3 w g 25 76 mmAq range Please list the reading here for future reference Initial dust collector differential pressure reading acros...

Страница 29: ...m the inner door gasket Pull the QuickSeal door handle away from the dust collector until the handle makes a 90 angle with the door cover The filter access door is now in an unlatched position Lift th...

Страница 30: ...TRIC SHOCK HAZARD All electrical work should be performed by a qualified electrician in accordance with local electrical codes Disconnect electrical power before installing or servicing any electrical...

Страница 31: ...old or burst rupture panel While loosening the capture frame bolting take care to avoid the sharp edges of the rupture panel as these can cause severe cuts and or abrasions Remove the capture frame a...

Страница 32: ...ip hold downs 3 5 Loosen nuts 9 holding flat clip supports 2 on internal door edge 7 Check flat Clip supports 2 as directed above Rotate 90 so flat clip support 2 is parallel with the door edge 7 6 Pu...

Страница 33: ...ansformer etc Check for proper motor starter overload rating against full load amps on motor nameplate Adjust or replace overloads as required Ensure drum is properly sealed against drum lid package E...

Страница 34: ...0 115 VAC supply voltage to the timer board and voltage output from timerboards to solenoid valves Consult DPM DPC Pulse Control Panel Installation and Operation Manual for additional assistance Reduc...

Страница 35: ...30 Revised 04 15 SFC Cartridge Dust Collector 7 ILLUSTRATED PARTS FIGURE 21 SFC Series 44 10330 0001 FIGURE 22 SFC Series Explosion Vents...

Страница 36: ...Lid 8A 45 10034 0020 20 Gallon Drum Lid 9 45 10022 0055 55 Gallon Quick Release Collar 9A 45 10022 0020 20 Gallon Drum Quick Release Collar 10 15 0233 14 Hose Clamp 11 15 0202 14 Flexible Duct 12 18 0...

Страница 37: ...This page intentionally left blank...

Страница 38: ...This page intentionally left blank...

Страница 39: ...This page intentionally left blank...

Страница 40: ...to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice Preside...

Отзывы: