cartridge Dust collector

Disconnect lifting slings and spreader bars used for 

installation.
apply sealant to the next hoppers that will receive a

filter module (refer to figure 7). apply sealant to the

side bolting flange of the next filter module to be

installed using the “figure 8” pattern (refer to figure 7,

Detail B). Place this module on its hopper. use the 

hardware provided (refer to figure 7, Detail B).
Place this module on its hopper. use the hardware 

provided (refer to figure 7, Detail B) and bolt the 

module sections together. Bolt the filter module to

the hopper (refer to figure 7, Detail a). Securely tighten

all hardware at the filter module and hopper. recheck

leg assembly sway braces to ensure they are tight.

install fasteners (bolt, flat washer, lock-washer, nut) to

all four pry locations..
Disconnect lifting slings and spreader bars used for 

installation.
repeat this process until all the module sections are in 

place, securely fastened and anchored to the foundation. 

recheck all hardware connections to make certain they 

are securely tightened. remove lift slings and spreader 

bars and clear all tools from the work area.

NOTE:

   Make certain all bolts (including the anchor 

bolts) are properly tightened before proceeding 

with the remainder of the installation.

install all cartridge filters removed at the beginning 

of the installation process and install the filter access 

doors (refer to Section 5.1).

3.4  ELECTRICAL INSTALLATION

ELECTRICAL SHOCK HAZARD

     all electrical work should be performed by a  

qualified electrician in accordance with local  

electrical codes. Disconnect electrical power before 

installing or servicing any electrical component.

GENERAL

Several types of standard electrical components can 

be installed to control and monitor your dust collector.  

a VfD or a motor starter circuit (combination starter 

panel) is required to safely start and stop the system.  

a properly sized circuit breaker or fused disconnect 

is also required to safely work on and service the 

electrical system.  in addition, a 115/1/60 (2 amp) 

control circuit is required for the pulse control panel.  

Some or all of the above items may be included in the 

controls package you purchased from uaS. any one 

of the following control combinations can be used:

•  Motor starter with Digital Pulse Monitor (DPM) for 

continuous pulse cleaning.

•  Motor starter with Digital Pulse Control (DPC) for 

on-demand pulse cleaning.

• VFD with DPM for continuous pulse cleaning.

• VFD with DPC for on-demand pulse cleaning.

refer to uaS sales order to verify the control 

configuration purchased with your unit and whether 

additional items are required to control and operate 

your system.

3.4.1 MOUNTING THE CONTROLS

Mount the VfD or combination starter panel for the 

fan motor in a convenient location.  it is recommended 

that these controls be mounted on a wall or pedestal 

in an area subject to minimal vibration and electrical 

noise.  Mounting hardware is provided by the 

customer or the contractor.  if the panel includes 

the DPM or the DPc gauge and uaS timer control 

board, then the location of the panel must within close 

proximity of the dust collection unit as shown in figure 

8.  for additional setup and installation information 

refer to the VfD and/or DPM/DPc owner’s Manuals 

provided.

   avoid mounting the panel on the collector due to 

vibration generated from blower assembly and the 

pulsing system.

 

for all pulse control panels, connect the black plastic 

pressure tubing (25’ [7.5 meters] provided by uaS) to 

the panel fittings and the Sfc unit. connect the dirty air 

plenum of the Sfc to the high pressure port (dirty air) 

on the panel as shown in figure 8. connect the clean 

air plenum of the Sfc to the low pressure port (clean 

air) on the panel. 

3.4.2   SOLENOID VALVE ENCLOSURE 

WIRING

the solenoid valves at the dust collector must be 

wired correctly to the pulse control panel. refer to 

figure 9 when making connections from the pulse 

control panel to the solenoid valve enclosure(s).

Example:

 figure 9 shows the Sfc having ten valve 

locations per module. this means when the system 

pulses, “1” is the first pulse in the sequence, “2” is 

the second, “3” is the third, etc.
When multiple dust collector modules are installed,  

daisy chain the wiring so that each solenoid valve 

with the same module location will pulse at the 

same time. this means all #1 solenoid valves are 

connected together and wired to pulse control panel 

“out 1,” #2 solenoid valves are connected together 

and wired to pulse control panel “out 2,” etc. refer 

to figure 9 for the Sfc dust collector solenoid valve 

wiring information. When cleaning, the pulse valves 

sequence left to right, top to bottom.
unless specified on the uaS sales order, the customer 

will supply interconnecting material (conduit, wiring, 

etc.) from the pulse control panel to the Sfc.

   CAUTION

 

!

  D A N G E R

Содержание UAS SFC Series

Страница 1: ...Downward Flow Cartridge Dust Collector l Model SFC l PATENT NO 6 902 592 OWNER S MANUAL...

Страница 2: ...when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL ________________...

Страница 3: ...ogether Module Sections applies to 4 or more modules 6 3 4 Electrical Installation 11 3 4 1 Mounting the Controls 11 3 4 2 Solenoid Valve Enclosure Wiring 11 3 4 3 Heater Wiring 15 3 5 Compressed Air...

Страница 4: ...al 24 5 3 Servicing the Compressed Air Components 25 5 4 Servicing the Direct Drive Blower and Motor System 25 5 5 Servicing Cartridge Media 25 5 6 Servicing Optional Return Air Safety Filters HEPA AS...

Страница 5: ...t collector The unit should be inspected frequently and dirt removed to prevent excessive accumulation which may result in flash over or fire damage The SFC system should not be used to support person...

Страница 6: ...r are recommended to be located outside the building in non traffic areas even though the dust collector is equipped with an explosion vent 2 INTRODUCTION Thank you for selecting UAS dust collection e...

Страница 7: ...e pulse cleaning mechanism provides brief bursts of compressed air directed through the diaphragm valves toward the cartridge filter This pulsing action dislodges the collected particles from the medi...

Страница 8: ...installation kit Hopper assemblies will be shipped in pieces and will need to be assembled at the site The hopper sections are shipped in pieces for field assembly Position the legs as shown in Figure...

Страница 9: ...4 Revised 04 15 SFC Cartridge Dust Collector FIGURE 2 SFC Typical Single Unit Installation Diagram 44 10335 0001...

Страница 10: ...5 Revised 04 15 SFC Cartridge Dust Collector FIGURE 3 Recommended Unit Clearances 44 10337 0001...

Страница 11: ...mbly is equipped with four 1 2 13mm pry locations two holes on front flange and two holes on rear flange Refer to Figure 7 Detail C to aid in aligning the hopper flange with the module flange With fil...

Страница 12: ...7 Revised 04 15 SFC Cartridge Dust Collector FIGURE 4 Single Hopper SFC 44 10309 0001...

Страница 13: ...8 Revised 04 15 SFC Cartridge Dust Collector FIGURE 5 Multiple Hopper SFC 44 10309 0002...

Страница 14: ...9 Revised 04 15 SFC Cartridge Dust Collector FIGURE 6 Multiple Hopper SFC 44 10309 0003...

Страница 15: ...10 Revised 04 15 SFC Cartridge Dust Collector FIGURE 7 Multiple Modules SFC 44 10310 0001...

Страница 16: ...itor DPM for continuous pulse cleaning Motor starter with Digital Pulse Control DPC for on demand pulse cleaning VFD with DPM for continuous pulse cleaning VFD with DPC for on demand pulse cleaning Re...

Страница 17: ...12 Revised 04 15 SFC Cartridge Dust Collector FIGURE 8 SFC Pressure Gauge Installation 44 10333 0001 Rev A...

Страница 18: ...13 Revised 04 15 SFC Cartridge Dust Collector FIGURE 9 Solenoid Wiring to Pulse Controls for 2 3 4 and 5 Tier Units...

Страница 19: ...14 Revised 04 15 SFC Cartridge Dust Collector FIGURE 10 Pneumatic Valve Assembly 44 10332 0001...

Страница 20: ...fitting sealant on all compressed air supply pipe fittings and connections 3 6 ASSEMBLY OF OPTIONAL EQUIPMENT 3 6 1 BLOWER PACKAGE INSTALLATION TIP OVER HAZARD Anchor dust collector to concrete pad pr...

Страница 21: ...6 Revised 04 15 SFC Cartridge Dust Collector Figure 11 Legs Support Top Mount Blower 44 10331 0001 NOTE FOR BLOWERS 20 HP OR LARGER SUPPORT LEGS ARE REQUIRED TO BE INSTALLED UNDER THE CLEAN AIR PLENUM...

Страница 22: ...17 Revised 04 15 SFC Cartridge Dust Collector Figure 12 Abrasive Inlet Installation 44 10338 0001...

Страница 23: ...ing parts on the rotary air lock Do not allow any object to be placed in or near the rotary air lock during operation Verify rotary air lock rotation matches rotation arrows affixed to assembly 3 6 4...

Страница 24: ...ons NOTE The hopper s is not designed for dust storage The slide gate should remain open during normal operation 3 6 6 INLET COVER AND BLANK COVER PLATE INSTALLATION Inlet collar and blank cover plate...

Страница 25: ...20 Revised 04 15 SFC Cartridge Dust Collector Figure 16 EDAP Interconnection Figure 15 EDAP Installation 48 10007...

Страница 26: ...shipping routine for an assembled SFC unit is with an enclosed box truck This type of truck will not be able to transport an assembled 4 high unit due to height restrictions within the vehicle When s...

Страница 27: ...22 Revised 04 15 SFC Cartridge Dust Collector Figure 17 SFC Series Door Filter Installation 44 10329 0001...

Страница 28: ...n 1 5 w g 25 127 mmAq At start up this reading is generally in the 1 3 w g 25 76 mmAq range Please list the reading here for future reference Initial dust collector differential pressure reading acros...

Страница 29: ...m the inner door gasket Pull the QuickSeal door handle away from the dust collector until the handle makes a 90 angle with the door cover The filter access door is now in an unlatched position Lift th...

Страница 30: ...TRIC SHOCK HAZARD All electrical work should be performed by a qualified electrician in accordance with local electrical codes Disconnect electrical power before installing or servicing any electrical...

Страница 31: ...old or burst rupture panel While loosening the capture frame bolting take care to avoid the sharp edges of the rupture panel as these can cause severe cuts and or abrasions Remove the capture frame a...

Страница 32: ...ip hold downs 3 5 Loosen nuts 9 holding flat clip supports 2 on internal door edge 7 Check flat Clip supports 2 as directed above Rotate 90 so flat clip support 2 is parallel with the door edge 7 6 Pu...

Страница 33: ...ansformer etc Check for proper motor starter overload rating against full load amps on motor nameplate Adjust or replace overloads as required Ensure drum is properly sealed against drum lid package E...

Страница 34: ...0 115 VAC supply voltage to the timer board and voltage output from timerboards to solenoid valves Consult DPM DPC Pulse Control Panel Installation and Operation Manual for additional assistance Reduc...

Страница 35: ...30 Revised 04 15 SFC Cartridge Dust Collector 7 ILLUSTRATED PARTS FIGURE 21 SFC Series 44 10330 0001 FIGURE 22 SFC Series Explosion Vents...

Страница 36: ...Lid 8A 45 10034 0020 20 Gallon Drum Lid 9 45 10022 0055 55 Gallon Quick Release Collar 9A 45 10022 0020 20 Gallon Drum Quick Release Collar 10 15 0233 14 Hose Clamp 11 15 0202 14 Flexible Duct 12 18 0...

Страница 37: ...This page intentionally left blank...

Страница 38: ...This page intentionally left blank...

Страница 39: ...This page intentionally left blank...

Страница 40: ...to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice Preside...

Отзывы: