Nitrogen and pure air generator
NitroAir
9
4.
Installation
4.1.
Installation area requirements
4.1.1.
Moisture and particulate
In order to avoid any risk of damages to the electronic component, it is recom-
mended to install the generator in a environment where relative moisture and
particulate concentration are limited.
Moreover, the generator must be protected from dripping, rain and wind.
4.1.2.
Temperature
The temperature of the environment where the genertor is installed must be
between 5°C and 35°C.
Please avoid proximity to heat sources and exposition to sunlight beams.
4.2.
Positioning of the generator
4.2.1.
Handling
The packed generator can be handled using suitable equipments, such as a
“transpallet” or a forklift truck. Once unpacked, it can be moved by its own whe-
els.
e
The generator must always stand in vertical position, because it hasn’t been de-
signed to be layed.
4.2.2.
Packing removal
The generator is delivered on a dedicated pallet.
Remove packing, paying attention to not damaging the panels of the generator.
The generator must be lifted from the pallet using dedicated equipment or even
manually by at least 4 people.
If possible, conserve the original packing to guarantee adequate protection to
the instrument in case of future handling.
4.2.3.
Compressor block removal
e
Before of the generator start-up, remove the compressor block. Failure in per-
forming this operation will damage or break the generator.