Installation
10
Following the procedure to re-
move the compressor block:
1.
Unfasten the rear bottom panel.
2.
Disconnect the fan cable and
the ground cable.
3.
Detect the right angled profile
(in red) that blocks the
compressor on the base of the
generator.
4.
Unfasten the screws that block
it to the base (2).
5.
Unfasten the screws that block
it to the compressor (1).
6.
Remove the right angled
profile.
7.
Fasten the screws to the
compressor(1).
8.
Position the right
angled prifle on
the base of the
compressor in
correspondence of
the holes for the
blocking of the
screws.
9.
Position the
screws (2).
10.
Push the right
angled profile
toward the
generator (A).
11.
Fasten the screws
(2).
12.
Gently shake the
compressor to verify that it is free to move on the rubber feet and that it
doesn’t collide with the compressor block right angled profile.
13.
Connect again the fan and the ground cable.
14.
Fasten againg the rear lower panel.
The right angled profile must be mounted again in the correct way in case of
future handling.
A
2
2
1
1
All manuals and user guides at all-guides.com