Maintenance
22
7.3.
Maintenance schedule
In order to keep the efficiency of the generator and reduce failure risk, we re-
commend to follow the suggested maintenance schedule.
The following table indicates the frequency of the recommended maintenance,
expressed in “working hours” of the compressor.
e
Warranty is guaranteed only when using original parts.
e
Maintenance must be performed by specialized Claind technicians only.
e
If a correct maintenance schedule is not followed, the performance of the gene-
rator may no longer be ensured and it may lead to permanent damage to the
generator.
e
The part number R063388 contains 2 filter cartridge, to use 1 every 2000 h.
Part number
Description
2000 h 4000 h 6000 h 8000 h
R061040
CMS silencer 1/2”
2
R0539026
Maintenance compressor
kit
1
1
R0536033
Plastic silencer Gast
1
1
R062999001
Cut-off plate not returne
valve
3
3
R063388
Air coalescence for cartri-
dge
1
1
1
1
R0537056
Compressor Gast 71R555
230V~
MAINTENANCE KIT TO BE USED ->
423.93.0010
423.93.0011
Part number
Description
10000
h
12000
h
14000
h
16000
h
R061040
CMS silencer 1/2”
2
R0539026
Maintenance compressor
kit
1
R0536033
Plastic silencer Gast
1
1
R062999001
Cut-off plate not returne
valve
3
3
R063388
Air coalescence for cartri-
dge
1
1
1
1
R0537056
Compressor Gast 71R555
230V~
1
MAINTENANCE KIT TO BE USED ->
423.93.0012
423.93.0013