Nitrogen and pure air generator
NitroAir
15
6.2.
First start-up
6.2.1.
Setting
The geneator is supplied pre-set and ready to start production. The user can ac-
cess to the set up of some parameters (such as language, start-up way, etc.).
See par. Parameters setting.
6.2.2.
Operative sequence
1.
Verify that all the connection are performed according to what described in
Chapter 4 (INSTALLATION)
2.
Switch the generator on, switching ON the POWER key (see par. 6.3. Start-up of
the generator).
3.
Start the production of pure air pressing the START-STOP key.
4.
Wait till the generator enters the stand-by condition. In this condition, the
generator interrupts the normal cycles of production and the display shows the
message: STAND-BY.
5.
From this moment on, pure air is availble for the line.
6.
Let it flow in ambient air for at least 30 minutes, in order to clean the reservoir
and the line.
6.3.
Start-up of the generator
To start-up the generator, switch the POWER key on the front panel ON.
The display lights up and, after some seconds, a depressurization cycle is auto-
matically started. During this phase, that lasts maximum 30 seconds, following
message is displayed:
PLEASE WAIT
UNDER DEPRESSURIZATION
When the depressurization is over, the following message
is displayed:
GENERATOR READY
In this condition, the generator is ready to accept the command of start-up of
the production (see par. 6.4.) or of switch off (see par. 6.6.).
6.4.
Air and Nitrogen production
When the generator has ended the preparation phase (par. 6.3.) and the display
shows the message
GENERATOR READY
, you can start air and Nitrogen
production, in the following way: