Nitrogen and pure air generator
NitroAir
17
6.6.
Switch off the generator
6.6.1.
Correct Switch Off
The correct way to switch off the generator starts from the condition of
GENE-
RATOR READY
.The par. 6.5. describes how to reach that condition.
Switch the "POWER" key OFF to switch off the generator.
6.6.2.
Incorrect Switch Off
Avoid to switch off the generator without arresting it before following the in-
structions of par. 6.5.
This may happen accidentally or in case of black-out. In this case, to the next
start-up of the generator the following message will appear:
WARNING
INCORRECT SWITCH OFF
To suppress the alarm, press function key
.
6.7.
Display of parameters
6.7.1.
Display of the status of the generator
During production, the main page of the display shows the following message:
PRODUCTION
In order to have more information on the status of the generator, press the up
arrow key
. The display will show the following page:
ZZZ
YYY
XXX
00,0
00,0
000
Where:
ZZZ
= status of the compressed air, in bar
YYY
= status of the nitrogen production, in bar
XXX
= status of the air production, in bar
The values are continuosly updated in order to verify the correct operation of the
generator
To exit from this page and to come back to the main page, press the down arrow
key
.