Claind NitroAir - ваш надежный партнер для быстрой и эффективной работы. Скачайте бесплатное руководство пользователя с нашего сайта, чтобы узнать больше о возможностях данного продукта. Просто перейдите на manualshive.com и загрузите руководство.
User’s manual
Nitrogen and pure air generator
NitroAir
All manuals and user guides at all-guides.com
all-guides.com
Страница 1: ...User s manual Nitrogen and pure air generator NitroAir All manuals and user guides at all guides com a l l g u i d e s c o m...
Страница 2: ...afety 4 3 Description of the generator 6 4 Installation 9 5 Disassembly and transport 13 6 Use 14 7 Maintenance 20 8 Troubleshooting 23 9 Guarantee 25 10 Declaration of conformity 26 11 Notes 27 All m...
Страница 3: ...on we assume that the user of this Manual is experienced in the use of pneumatic components and in particu lar he is familiar with the safety issues regarding the use of compressed air The following s...
Страница 4: ...FROM RAIN AND WIND c It is strictly forbidden to OPEN the generator when it is connected to the power supply FATAL ELECTROCUTION HAZARD e Repairs and controls must be performed only by SPECIALIZED TE...
Страница 5: ...d to explosion hazard due to the structural failure of the components 2 4 Technical assistance e CLAIND disclaims any responsibility resulting from improper use of the genera tor Before of performing...
Страница 6: ...safety valves of the generator n 1 power supply cable with Schuko plug n 2 swagelok connectors 1 8 male for copper tube external diameter 1 8 n 4 nut 1 8 Swagelok n 4 back ferrule Swagelok 1 8 n 4 fro...
Страница 7: ...ation The data of the present model are indicated on the related product sheet Dimensions Lenght 40 cm Width 53 cm Height 83 cm Weight 78 kg Dimensioni imballo Lenght 50 cm Width 64 cm Height 105 cm G...
Страница 8: ...itch A AIR PRESSURE REGULATOR is needed to regulate the output pressure of pure air B CONNECTOR for the power cable it includes the slot for the main FUSE whose specification are listed on the B label...
Страница 9: ...generator can be handled using suitable equipments such as a transpallet or a forklift truck Once unpacked it can be moved by its own whe els e The generator must always stand in vertical position bec...
Страница 10: ...r 1 8 Position the right angled prifle on the base of the compressor in correspondence of the holes for the blocking of the screws 9 Position the screws 2 10 Push the right angled profile toward the g...
Страница 11: ...of the automatic type The supply includes two kinds of connectors one to perform the connection with the 1 8 copper tube for pure aire and Nitrogen A and the other one to connect the silencer to the...
Страница 12: ...y cable 2m lenght Schuko plug IEC320 C13 4 5 Warning e In case that even momentaneus failures in gas supply due to interruption of the power supply the intervention of a power protection a failure of...
Страница 13: ...sten the screws 2 that block the right angled profile on the base of the compressor 6 Position the right angled profile so that the screws 1 are lodged in the holes 7 Position the screws 2 8 Fasten th...
Страница 14: ...e display is made up of two lines of 20 characters each Usually the functions or parameters are displayed on the upper line and the re lated status and values are displayed in the lower line Should th...
Страница 15: ...moment on pure air is availble for the line 6 Let it flow in ambient air for at least 30 minutes in order to clean the reservoir and the line 6 3 Start up of the generator To start up the generator s...
Страница 16: ...y lasts 30 60 seconds the following message is displayed PLEASE WAIT UNDER DEPRESSURIZATION e PLEASE NOTE during an allarm block of production the START STOP key isn t operative At the end of depressu...
Страница 17: ...will appear WARNING INCORRECT SWITCH OFF To suppress the alarm press function key 6 7 Display of parameters 6 7 1 Display of the status of the generator During production the main page of the display...
Страница 18: ...you have to switch the generator on pressing for some seconds the Function key The data will be sequenced as indicated in the table above To modify them press the arrow keys To acquire the set value p...
Страница 19: ...he grenerator see par 3 3 1 e The default regulation is 0 0 bar vent closed 6 8 4 Regulation of the minimum Nitrogen pressur alarm To access to the parameter press the function key from the main menu...
Страница 20: ...function key After that the message disappears to proceed with normal operation At the next start up the generator asks if the maintenance operation has been performed displaying the following messag...
Страница 21: ...e Maintenance kit Part number Exhausting time 0 4000 h 0 8000 h 0 12000 0 16000 h Maintenance kit 2000 4000 h 423 93 0010 1 1 1 1 Maintenance kit 6000 8000 h 423 93 0011 1 1 1 Maintenance kit 10000 12...
Страница 22: ...art number R063388 contains 2 filter cartridge to use 1 every 2000 h Part number Description 2000 h 4000 h 6000 h 8000 h R061040 CMS silencer 1 2 2 R0539026 Maintenance compressor kit 1 1 R0536033 Pla...
Страница 23: ...ESSURE set value To silence the alarm press the function key To exhit from warning condition you have to allow to the pressure in the reser voir to increase again over the minimum value reducing the o...
Страница 24: ...the value of the pressure may overcome the maximum available generating a danger condition Altough the generator is equipped with a safety valve that prevent the pressure from reaching extreme values...
Страница 25: ...RKS CLAIND and doesn t cover the call fee of the technician to reach the seat of the customer Warranty covers EXCLUSIVELY THE COST COMING FROM MANUFACTURING DEFECTS and doesn t include 1 Damages due t...
Страница 26: ...regards is fully in conformity with the following rules 2014 30 EC Direttiva compatibilit elettromagnetica EMC Electromagnetic compatibility directive 2014 35 EC Direttiva bassa tensione LV Low voltag...
Страница 27: ...Nitrogen and pure air generator NitroAir 27 11 Notes All manuals and user guides at all guides com...
Страница 28: ...Claind srl Via Regina 24 22016 Tremezzina Loc Lenno CO Italy Tel 39 0344 56603 Fax 39 0344 56627 e mail service claind it NitroAir eng Rev7 fm All manuals and user guides at all guides com...