Hydrogen generator
Hydro200
5
2.2.
Safety devices
MAXIMUM PRESSURE:
The maximum volume of hydrogen that can be stored
in the generator is 100ml . Maximum operating pressure is 4 bar.
There is a double pressure control.
• One is a pressure sensor, via the control system, which shuts down the genera-
tor when pressure value exceeds by 0.5 bar the set value;
• The other is a pressure switch, independent from the control system, which shu-
ts down the generator when pressure value exceed 4.5 bar;
HYDROGEN-OXYGEN MIXTURE:
The formation of potentially hazardous
hydrogen-oxygen mixtures inside the generator is prevented by:
• Special electrodes (patented) for the production of hydrogen which prevent oxy-
gen from mixing with the hydrogen.
• A forced ventilation system prevents the formation of hydrogen pockets due to
possible gas leaks. Any significant gas leaks are also indicated by the control sy-
stem.
2.3.
Technical assistance
The CLAIND technical assistance can be contacted as follows:
Tel.
++39 0344 56603
Fax
++39 0344 56627
e-mail: [email protected]