22
7.5.
Drier replacement
• Turn off the generator as described in
par. 6.4. Stop the generator and par.
6.5. Generator shutdown
• Disconnect the electric power cable
• Prepare the required material (figure
A
):
- a drier recharge
- 8mm Allen key
- connection container (approx. 500
ml)
- funnel
• Loosen the lower cap by means of the
8mm Allen key(figure
B
)
• Remove the cap and drain the conten-
ts of the drier hose into the collection
container (figure
C
)
• Refit the lower cap by means of the
8mm Allen key
• Remove the top cap
• Pour the contents of the drier recharge
into the drier hose by means of the
funnel (figure
D
)
• Refit the top cap by means of the Allen
key
e
To avoid exposing the drier to humidi-
ty in the ambient air, open the rechar-
ge cartridge only at the time of
transfer and close the drier hose as
soon as recharging is complete
B
A
C
D