Use
14
The display illuminates and, after a few seconds, a depressurisation cycle is star-
ted automatically. During this phase, lasting maximum 60 seconds, the following
message is displayed:
WAIT…
DEPRESSURISATION IN PROGRESS
At the end of depressurisation, the following message is displayed:
GENERATOR READY
In this condition, the generator is ready to receive the production start-up com-
mand (see par. 6.3.) or shutdown command (see par. 6.5.).
6.3.
Hydrogen production
When the generator has completed the preparation phase (par. 6.2.) and the
message
GENERATOR READY
is displayed, hydrogen production can be
started up as follows:
Press the operation key START/STOP.
The production cycle is started up and the following message is displayed:
PRODUCTION
X.XX bar YYY Nml/min
where:
X.XX
= hydrogen pressure, expressed in
bar
Y.YY
= instant quantity of hydrogen produced, expressed in
normal millilitres
per minute
6.4.
Stop the generator
At any time during production the generator can be stopped by pressing the key
START/STOP.
Depending on the phase activated, the generator starts to depressurise imme-
diately, or awaits conclusion of the production cycle before activating depressu-
risation.
During depressurisation, which usually lasts from 30 to 60 seconds, the following
message is displayed:
WAIT…
DEPRESSURISATION IN PROGRESS