5-5
CONTROL CHANNEL
The Control Channel allows the operator to Calibrate and set Limits and configure the scroller from the
console. The Control Channel must remain stable at the appropriate level for 2 seconds to engage function.
CONTROL CHANNEL VALUES
WHEN USING DIRECT DMX SCROLLERS
WHEN USING WYBRON COLORAM II
WHEN USING WYBRON CXI
0%
Operation
0%
Operation
0%
Operation
5%
unused
5%
Calibrate scroller***
5%
Calibrate scroller***
10%
Calibrate All Attributes
10%
Calibrate All Attributes
10%
Calibrate All Attributes
15%
unused
15%
Motor slow
15%
unused
20%
Calibrate Pan
20%
Calibrate Pan
20%
Calibrate Pan
25%
unused
25%
Motor normal
25%
unused
30%
Calibrate Tilt
30%
Calibrate Tilt
30%
Calibrate Tilt
35%
unused
35%
Fan slow
35%
Fan slow
40%
Calibrate Iris
40%
Calibrate Iris
40%
Calibrate Iris
45%
unused
45%
Fan normal
45%
Fan normal
50%
Calibrate Focus
50%
Calibrate Focus
50%
Calibrate Focus
55%
Cut Power to scroller***
55%
Fan off
55%
Fan off
60%
Set Pan Low Limit
60%
Set Pan Low Limit
60%
Set Pan Low Limit
65%
Set Pan High Limit
65%
Set Pan High Limit
65%
Set Pan High Limit
70%
Set Tilt Low Limit
70%
Set Tilt Low Limit
70%
Set Tilt Low Limit
75%
Set Tilt High Limit
75%
Set Tilt High Limit
75%
Set Tilt High Limit
80%
Set Iris Low Limit
80%
Set Iris Low Limit
80%
Set Iris Low Limit
85%
Set Iris High Limit
85%
Set Iris High Limit
85%
Set Iris High Limit
90%
Set Focus Low Limit
90%
Set Focus Low Limit
90%
Set Focus Low Limit
95%
Set Focus High Limit
95%
Set Focus High Limit
95%
Set Focus High Limit
100% unused
100% unused
100% unused
***NOTE: 55% (when using direct DMX scrollers) and 5% (when using Wybron Coloram II and CXI) allow
the operator to remotely recalibrate the scroller. Direct DMX scrollers (using control channel
55%) will recalibrate once the control channel reverts to operation mode; Wybron Coloram II
and CXI will recalibrate after 2 seconds when control channel is set to 5%.
SETTING LIMITS WITH THE CONTROL CHANNEL
1. Bring the Control Channel to the appropriate level.
2. Bring the channel that operates the attribute to the desired level.
***NOTE: The attribute channel level must change once before the desired level can be selected. If the
attribute channel is already at the desired level move it off of the desired level and then back to the
desired level -
This is to prevent inadvertent limit selection during programming
.
3. Bring the Control Channel to 0.
4. Bring the attribute channel to 0 to complete the setting of limits.
-30-