C-6
Cisco UCS C240 Server Installation and Service Guide
OL-25761-01
Appendix C RAID Controller Considerations
Factory-Default Option ROM Settings
Factory-Default Option ROM Settings
describes the option ROM (OPROM) settings for card slots that are made at the factory for
various configurations. The version of server and the number of CPUs affect the OPROM settings.
Note
If an option is listed as “not allowed” in
, that is because it is not supported in the particular
configuration described in that table row. See the footnotes below the table for more information.
For additional information about RAID controller support, see
Supported RAID Controllers and
.
Table C-3
Cisco UCS C240 Factory-Default Option ROM Settings
Server Version
Number
of CPUs
Embedded
SW RAID
Enabled?
Mezz. RAID
Controller
Installed?
PCIe RAID
Controller 1
Installed?
PCIe RAID
Controller 2
Installed?
LOM
ports
Comments
C240 SFF 24 HDD/
C240 LFF 12 HDD
1
Not
allowed
1
1. The embedded SW RAID controller is supported only with the 16 HDD direct-connect backplane. It is not supported with an expander.
Not allowed
2
2. In a single-CPU configuration, the mezzanine card slot is not supported.
Installed
:
PCIe slot 3
enabled
3
3. In a single-CPU configuration, PCIe slots 4 and 5 are not supported.
Not allowed
Always
enabled
All other OPROM
is disabled.
Requires expander.
C240 SFF 24 HDD/
C240 LFF 12 HDD
2
Not allowed
Installed
:
connector
enabled
Not allowed
4
4. You cannot mix controller types in a server. A PCIe-style controller cannot be used when a mezzanine-style controller is used.
Not allowed
Always
enabled
All other OPROM
is disabled.
Requires expander.
C240 SFF 24 HDD/
C240 LFF 12 HDD
2
Not allowed Not allowed
5
5. You cannot mix controller types in a server. A mezzanine-style controller cannot be used when a PCIe-style controller is used.
Installed
:
PCIe slot 4
enabled
Not allowed
Always
enabled
All other OPROM
is disabled.
Requires expander.
C240 SFF 16 HDD
1
Enabled
Not allowed
6
Not allowed
Not allowed
Always
enabled
All other OPROM
is disabled.
Maximum 8 drives.
C240 SFF 16 HDD
1
Not allowed Not allowed
Installed
:
PCIe slot 3
enabled
Not allowed
Always
enabled
All other OPROM
is disabled.
Maximum 8 drives.
C240 SFF 16 HDD
2
Enabled
Not allowed
Not allowed
Not allowed
Always
enabled
All other OPROM
is disabled.
Maximum 8 drives.
C240 SFF 16 HDD
2
Not allowed
Installed
:
connector
enabled
Not allowed
Not allowed
Always
enabled
All other OPROM
is disabled.
Maximum 8 drives.
C240 SFF 16 HDD
2
Not allowed Not allowed
Installed
:
PCIe slot 4
enabled
Absent
Always
enabled
All other OPROM
is disabled.
Maximum 8 drives.
C240 SFF 16 HDD
2
Not allowed Not allowed
Installed
:
PCIe slot 4
enabled
Installed
:
PCIe slot 3
enabled
Always
enabled
All other OPROM
is disabled.
Max. 16 drives
7
.
Содержание UCS C240
Страница 12: ...xii Cisco UCS C240 Server Installation and Service Guide OL 25761 01 Preface ...
Страница 14: ...xiv Cisco UCS C240 Server Installation and Service Guide OL 25761 01 Preface ...
Страница 156: ...D 2 Cisco UCS C240 Server Installation and Service Guide OL 25761 01 Appendix D Installation for Cisco UCS Integration ...