A-4
Cisco UCS C240 Server Installation and Service Guide
OL-22326-01
Appendix A Server Specifications
Environmental Specifications
Environmental Specifications
lists the environmental specifications for the server.
Table A-5
Environmental Specifications
Description
Specification
Temperature, operating:
41 to 104°F (5 to 40°C)
Derate the maximum temperature by 1°C per every
305 meters of altitude above sea level.
Temperature, non-operating
(when the server is stored)
–40 to 149°F (–40 to 65°C)
Humidity (RH), noncondensing
10 to 90%
Altitude, operating
0 to 10,000 feet
Altitude, non-operating
(when the server is stored)
0 to 40,000 feet
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
5.8
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
43