Voice Parameters
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
99
6
<Emergency_Number_1_>
<Emergency_Number_2_>
Comma separated list of emergency number patterns. If
outbound call matches one of the pattern, the ATA will disable
hook flash event handling. The condition is restored to normal
after the call ends. Blank signifies that there is no emergency
number. Maximum number length is 63 characters.
Default setting: blank
<Mailbox_ID_1_>
<Mailbox_ID_2_>
Enter the ID number of the mailbox for this line.
Default setting: blank
<Proxy_1_> through <Proxy_13_>
SIP proxy server for all outbound requests.
Default setting: blank
<Outbound_Proxy_1_> through
<Outbound_Proxy_13_>
SIP Outbound Proxy Server where all outbound requests are
sent as the first hop.
Default setting: blank
<Use_Outbound_Proxy_1_> through
<Use_Outbound_Proxy_13_>
Enables the use of an Outbound Proxy. If set to no, the
Outbound Proxy and Use OB Proxy in Dialog parameters are
ignored.
Default setting: no
<Use_OB_Proxy_In_Dialog_1_> through
<Use_OB_Proxy_In_Dialog_13_>
Whether to force SIP requests to be sent to the outbound
proxy within a dialog. Ignored if the parameter Use Outbound
Proxy is no, or the Outbound Proxy parameter is empty.
Default setting: yes
<Register_1_> through <Register_13_>
Enable periodic registration with the Proxy parameter. This
parameter is ignored if Proxy is not specified.
Default setting: yes
<Make_Call_Without_Reg_1_> through
<Make_Call_Without_Reg_13_>
Allow making outbound calls without successful (dynamic)
registration by the unit. If No, dial tone will not play unless
registration is successful.
Default setting: no
<Register_Expires_1_> through
<Register_Expires_13_>
Expires value in sec in a REGISTER request. The ATA will
periodically renew registration shortly before the current
registration expired. This parameter is ignored if the Register
parameter is no. Range:
0 – (2
31
– 1) sec.
Default setting: 3600