Voice Parameters
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
135
6
<CPC_Delay>
Delay in seconds after caller hangs up when the ATA starts
removing the tip-and-ring voltage to the attached equipment
of the called party. The range is 0–255 seconds. This feature
is generally used for answer supervision on the caller side to
signal to the attached equipment when the call has been
connected (remote end has answered) or disconnected
(remote end has hung up) This feature should be disabled for
the called party (in other words, by using the same polarity for
connected and idle state) and the CPC feature should be used
instead.
Without CPC enabled, reorder tone will is played after a
configurable delay. If CPC is enabled, dial tone will be played
when tip-to-ring voltage is restored. Resolution is 1 second.
Default setting: 2
<CPC_Duration>
Duration in seconds for which the tip-to-ring voltage is
removed after the caller hangs up. After that, tip-to-ring
voltage is restored and the dial tone applies if the attached
equipment is still off-hook. CPC is disabled if this value is set
to 0. Range: 0 to 1.000 second. Resolution is 0.001 second.
Default setting: 0
(CPC disabled)
<Call_Return_Code>
Call Return Code This code calls the last caller.
Default setting: *69
<Call_Redial_Code>
Redials the last number called.
Default setting: *07
<Blind_Transfer_Code>
Begins a blind transfer of the current call to the extension
specified after the activation code.
Default setting: *98
<Call_Back_Act_Code>
Starts a callback when the last outbound call is not busy.
Default setting: *66
<Call_Back_Deact_Code>
Cancels a callback.
Default setting: *86
<Call_Back_Busy_Act_Code>
Starts a callback when the last outbound call is busy.
Default setting: *05