![Cisco SPA1112 Скачать руководство пользователя страница 134](http://html.mh-extra.com/html/cisco/spa1112/spa1112_provisioning-manual_63552134.webp)
Voice Parameters
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
134
6
<Reorder_Delay>
Delay after far end hangs up before reorder tone is played. 0 =
plays immediately, inf = never plays. Range: 0–255 seconds.
Default setting: 5.
<Call_Back_Expires>
Expiration time in seconds of a call back activation. Range: 0–
65535 seconds.
Default setting: 1800
<Call_Back_Retry_Intvl>
Call back retry interval in seconds. Range: 0–255 seconds.
Default setting: 30
<Call_Back_Delay>
Delay after receiving the first SIP 18x response before
declaring the remote end is ringing. If a busy response is
received during this time, the ATA still considers the call as
failed and keeps on retrying.
Default setting: 0.5
<VMWI_Refresh_Intvl>
Interval between VMWI refresh to the device.
Default setting: 0
<Interdigit_Long_Timer>
Long timeout between entering digits when dialing. The
interdigit timer values are used as defaults when dialing. The
Interdigit_Long_Timer is used after any one digit, if all valid
matching sequences in the dial plan are incomplete as dialed.
Range: 0–64 seconds.
Default setting: 10
<Interdigit_Short_Timer>
Short timeout between entering digits when dialing. The
Interdigit_Short_Timer is used after any one digit, if at least
one matching sequence is complete as dialed, but more
dialed digits would match other as yet incomplete sequences.
Range: 0–64 seconds.
Default setting: 3