![Cisco SPA1112 Скачать руководство пользователя страница 116](http://html.mh-extra.com/html/cisco/spa1112/spa1112_provisioning-manual_63552116.webp)
Voice Parameters
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
116
6
<RTP_ToS/DiffServ_Value_1> through
<RTP_ToS/DiffServ_Value_5_>
ToS/DiffServ field value in UDP IP packets carrying RTP data.
Default setting: 0xb8
<RTP_CoS_Value_1_> through <RTP_
CoS_Value_5_>
CoS value for RTP data. Valid values are 0 through 7.
Default setting: 6
<Network_Jitter_Level_1_> through
<Network_Jitter_Level_5_>
Determines how jitter buffer size is adjusted by the ATA. Jitter
buffer size is adjusted dynamically. The minimum jitter buffer
size is 30 milliseconds or (10 millis current RTP
frame size), whichever is larger, for all jitter level settings.
However, the starting jitter buffer size value is larger for higher
jitter levels. This setting controls the rate at which the jitter
buffer size is adjusted to reach the minimum. Select the
appropriate setting: low, medium, high, very high, or extremely
high.
Default setting: high
<Jitter_Buffer_Adjustment_1_> through
<Jitter_Buffer_Adjustment_5_>
Choose yes to enable or no to disable this feature.
Default setting: yes
<SIP_Transport_1_> through <SIP_
Transport_5_>
The TCP choice provides “guaranteed delivery”, which
assures that lost packets are retransmitted. TCP also
guarantees that the SIP packages are received in the same
order that they were sent. As a result, TCP overcomes the
main disadvantages of UDP. In addition, for security reasons,
most corporate firewalls block UDP ports. With TCP, new
ports do not need to be opened or packets dropped, because
TCP is already in use for basic activities such as Internet
browsing or e-commerce. Options are: UDP, TCP, TLS.
Default setting: UDP
<SIP_Port_1_> through <SIP_Port_5_>
Port number of the SIP message listening and transmission
port.
Default setting: 5060
<SIP_100REL_Enable_1_> through
<SIP_100REL_Enable_5_>
To enable the support of 100REL SIP extension for reliable
transmission of provisional responses (18x) and use of PRACK
requests, select yes. Otherwise, select no.
Default setting: no
<EXT_SIP_Port_1_> through <EXT_SIP_
Port_5_>
The external SIP port number.
Default setting: blank