Administration
System Logs
Cisco Small Business SG200 Series 8-port Smart Switches Administration Guide
49
4
•
Log Aggregation Interval
—If Log Aggregation is enabled, specify the
interval in seconds. Consecutive messages that are received within this
interval will be aggregated into a single log message. The range is 15
seconds to 120 seconds.
•
RAM Memory Logging
—Select to enable logging in RAM.
•
Flash Memory Logging
—Select to enable logging in flash memory.
•
Flash Log Size
—Enter the maximum number of log messages to store in the
flash memory log.
STEP 3
Enable the event severity levels to be logged for each log type. The severity levels
are listed from the highest to the lowest severity, as follows:
•
Emergency
—System is not usable.
•
Alert
—Action is needed.
•
Critical
—System is in a critical condition.
•
Error
—System is in error condition.
•
Warning
—System warning has occurred.
•
Notice
—System is functioning properly, but a system notice has occurred.
•
Informational
—Device information.
•
Debug
—Provides detailed information about an event.
NOTE:
When you select a severity level, any events of that level or higher are
automatically selected for logging.
STEP 4
Click
Apply
. Your changes are saved to the Running Configuration.