Fault Management of the RF Gateway 1
78-4025112-01 Rev H0
65
Fault Management of the RF Gateway 1
The RF Gateway 1 supports automatic detection and user notification of changes in
the system. Changes may be classified as either Events or Alarms. Alarms carry a
state while events are important instances that occur in time and are reported. For
example,
Link Lost
and
Link OK
are two well-defined states and are associated with
an alarm.
Events Startup
,
Configuration Backup
, and
Second Power Supply Inserted
do
not have a state but are important events reported by the system.
System Alarms
System Alarms are conditions with state that occur on the system that the user may
want to be aware of. The RF Gateway 1 provides user notification of changes in
alarm state. These notifications can be via SNMP traps, system log or the front panel
fault LED. System alarms can not be masked or filtered and will always be indicated
on the system.
The default alarms supported by the system are defined in the alarm configuration
area of the database. The default alarm configuration parameters include items such
as alarm label, severity, mask, threshold, and enabled notifications. These
parameters are defaults and are not configurable through the web interface.
While active, the system maintains additional information on each of the alarms
such as alarm originator, state, instance, and other descriptive details including
triggering threshold, actual value, and units. Alarms have two possible state values,
Alarm and Clear. Each alarm has two possible severity levels, Critical or Major. The
supported alarms are described in the following table.
Name
Severity
Description
Power On Self Test Critical
A failure during power on self test has been detected.
GbE Port Link
Critical
A GbE port has changed state.
UDP Traffic
Major
Complete loss of UDP traffic has been detected.
Fan Failure
Major
One of the four chassis fans RPM is measuring below
threshold.
FPGA Temperature Major
A FPGA board temperature has exceeded the threshold.
Power Supply
Shutdown
Critical
A power supply has indicated an imminent shutdown.
DTI Port Link
Critical
A DTI port has changed state.
Power Supply
Voltage
Critical
One or more power supply voltages is performing outside of
the acceptable threshold.
Continuity Count
Error
Critical
MPEG continuity counts have been detected on one or more
elementary streams.
Содержание RF Gateway 1 Modules
Страница 1: ...78 4025112 01 R ev H0 Cisco RF Gateway 1 Configuration Guide ...
Страница 2: ......
Страница 10: ...Contents viii 78 4025112 01 Rev H0 Electrical GbE SFP Transceiver 254 Glossary 255 Index 259 ...
Страница 20: ...Important Safety Instructions xviii 78 4025112 01 Rev H0 ...
Страница 24: ......
Страница 26: ......
Страница 48: ......
Страница 128: ......
Страница 150: ......
Страница 156: ...Chapter 8 M CMTS Data DEPI CP Operation 132 78 4025112 01 Rev H0 Result Input monitoring is shown for each GbE port ...
Страница 165: ...Feature Page 78 4025112 01 Rev H0 141 Feature Page 1 Navigate to the Maps page 2 Select Unreferenced PID Maps ...
Страница 170: ......
Страница 174: ......
Страница 178: ......
Страница 192: ......
Страница 248: ......
Страница 257: ...Operational Considerations 78 4025112 01 Rev H0 233 Video Stream Map Editor Video Map Advanced Settings ...
Страница 260: ......
Страница 272: ......
Страница 282: ......