background image

Installing the Shelf Brackets and Shelf

 17.5 in. (44.45 cm) Opening

Before You Begin

Review the following illustration and table.

Figure 13: Installing the Shelf Brackets on a Rack with a 17.5 in. (44.45 cm) Opening

Right shelf bracket

4

Left rail

1

Support shelf

5

Left shelf bracket

2

M4 flathead Phillips screws

6

Right rail

3

Procedure

Step 1

Position the support flange of the left shelf bracket on the front of the left rail, as shown in the figure.
(Alternatively, you can position the support flange of the left shelf bracket on the back of the left rail.)

Step 2

Secure the shelf bracket to the rack by using four screws.

Catalyst 6880-X Switch Hardware Installation Guide    

   OL-30827-02

39

Installing the Switch

Installing the Rack-Mount Shelf Kit

Содержание Catalyst 6880-X

Страница 1: ...e First Published December 20 2013 Last Modified March 18 2014 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Text Part Number OL 30827 02 ...

Страница 2: ...encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not ...

Страница 3: ... Ports 3 Half Wide Modular Slots 4 Port Card Overview 5 Power Supply Slots 6 Management Port 7 USB Port Type B 7 USB Type A Port 7 Console Port 8 System Reset Button 8 Fan Tray 8 LED Indicators 8 System Status LED 9 Status LED on the Modular Port Card 9 System ID LED 9 ID LED on the Modular Port Card 10 SFP Port LEDs 10 Management Port LED 11 Fan Tray LEDs 12 AC Input Power Supply LEDs 13 Catalyst...

Страница 4: ...amage 26 Attaching the ESD Wrist Strap 26 Power Requirements 27 Power Connection Guidelines for AC Powered Systems 28 Power Connection Guidelines for DC Powered Systems 28 Cabling Requirements 29 Site Preparation Checklist 29 C H A P T E R 3 Installing the Switch 33 Installation Tasks 33 Safety Warnings 34 Rack Mounting Guidelines 35 Unpacking the Switch 36 Chassis Installation Kits and Cable Guid...

Страница 5: ...Installing SFP and SFP Transceiver Modules 48 Removing SFP or SFP Transceiver Modules 50 Verifying Switch Chassis Installation 51 Online Diagnostics 51 C H A P T E R 4 Installing and Removing Power Supplies 53 Power Supply Overview 53 Installing Power Supplies 55 Before You Begin 55 Inserting the Power Supply 56 Connecting to the Power Source 57 Before You Begin 57 Connecting to an AC Power Source...

Страница 6: ...Supply Module Specifications 81 3000 W Power Supply AC Power Cords 82 Fan Module Specifications 90 Chassis and Module Power and Heat Values 90 A P P E N D I X B Module Connectors and Cable Specifications 93 Module Connectors 93 RJ 45 Connector 93 LC Connector 94 Cables and Adapters 94 SFP Module Cables 94 Cable Pinouts 95 Console Port Adapter Pinouts 96 Console Port Mode 2 Signaling and Pinouts 97...

Страница 7: ... Device Driver 109 Installing the Cisco Microsoft Windows XP USB Driver 109 Installing the Cisco Microsoft Windows 2000 USB Driver 110 Installing the Cisco Microsoft Windows Vista and Windows 7 USB Driver 110 Uninstalling the Cisco Microsoft Windows USB Driver 110 Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver 110 Using the Setup exe Program 111 Using the Add or Remove Programs Ut...

Страница 8: ...Catalyst 6880 X Switch Hardware Installation Guide viii OL 30827 02 Contents ...

Страница 9: ...his document uses the following conventions Description Convention Both the symbol and Ctrl represent the Control Ctrl key on a keyboard For example the key combination D or Ctrl D means that you hold down the Control key while you press the D key Keys are indicated in capital letters but are not case sensitive or Ctrl Commands and keywords and user entered text appear in bold font bold font Docum...

Страница 10: ...round the string or the string will include the quotation marks string Nonprinting characters such as passwords are in angle brackets Default responses to system prompts are in square brackets An exclamation point or a pound sign at the beginning of a line of code indicates a comment line Reader Alert Conventions This document may use the following conventions for reader alerts Means reader take n...

Страница 11: ...P modules documentation including compatibility matrixes at http www cisco com en US products hw modules ps5455 tsd_products_support_series_home html Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new a...

Страница 12: ...Catalyst 6880 X Switch Hardware Installation Guide xii OL 30827 02 Preface Obtaining Documentation and Submitting a Service Request ...

Страница 13: ...dels Table 1 Switch Models Description Switch Model 16 10 Gigabit SFP 1 Gigabit SFP or 100BASE FX SFP ports four port card slots two power supply slots It supports standard FIB ACL and NetFlow tables Catalyst 6880 X LE 16 10 Gigabit SFP 1 Gigabit SFP or 100BASE FX SFP ports four port card slots two power supply slots It supports larger FIB ACL and NetFlow tables Catalyst 6880 X Front Panel Compone...

Страница 14: ...agement port USB ports Console port System reset button LEDs Fan tray Figure 1 Catalyst 6880 X Switch Catalyst 6880 X Switch Hardware Installation Guide 2 OL 30827 02 Product Overview Front Panel Components ...

Страница 15: ...y on page 8 SFP and SFP Transceiver Module Ports The chassis contain 16 ports of 10 Gigabit Ethernet SFP or 100BASE FX fiber optic transceiver modules All ports support 1 Gigabit SFP 10 Gigabit SFP or 100BASE FX fiber optic SFP modules The ports also support Cisco Trust Security CTS and virtual switch link VSL and can operate as an Instant Access AI Parent in both 1 Gigabit and 10 Gigabit modes Th...

Страница 16: ...e Modular Slots The chassis has four half wide modular slots that accept pluggable port cards that can expand the capability of the switch For more detailed information about the modular port cards and their installation see the Installing the Modular Port Card chapter The chassis is delivered with modular slot blank covers already installed which must remain installed if the port cards are not us...

Страница 17: ...alled or a blank module installed in the half modular slots Description Port Card Model Multirate port card with standard tables This module has 16 10 Gigabit 1 Gigabit or 100BASE FX fiber optic slots which support 1 Gigabit SFPs 10 Gigabit SFP or 100BASE FX fiber optic modules C6880 X LE 16P10G Multirate port card with XL tables This module has 16 10 Gigabit 1 Gigabit or 100BASE FX fiber optic sl...

Страница 18: ...itch data_sheet_c78 728228 html Power Supply Slots The chassis has two slots that accept either two 3000 W AC input or two 3000 W DC input power supplies or one of each The chassis is delivered with power supplies already installed in the power supply slots If only one power supply is ordered then a blank cover is installed in the empty power supply slot which must remain installed if a power supp...

Страница 19: ...r The USB console port connection uses a USB Type A to Type B cable The USB console interface speeds are the same as the RJ 45 console interface speeds Windows PCs need a driver for the USB port The USB prefer mode is the default but it can be overridden using the command line interface CLI When this port is in USB prefer mode the RJ 45 console port will be disabled if both ports are connected For...

Страница 20: ...moval OIR The fan tray contains four high efficiency fans with variable speed settings and thermal sensors If one fan fails the speed of the others is increased and a minor alarm is triggered If a major fan tray failure occurs the system is shut down The individual fans are not field replaceable the entire fan tray must be replaced in the event of a major fan tray failure See Removing the Fan Tray...

Страница 21: ...arm Red Related Topics LED Indicators on page 8 Status LED on the Modular Port Card The Status LED indicates the status of the modular port card Table 3 Status LED Indicator Description Color State Port card is not operational Off Port card is operating normally without alarms Green Port card has triggered a minor environmental alarm Amber Port card has triggered a major environmental alarm or the...

Страница 22: ...ing blue SFP Port LEDs Each port on the port card is associated with an LED that indicates status Figure 5 Numbering of Ports and LEDs on Fixed and Modular Port Cards Even numbered ports left to right 2 4 6 8 10 12 14 and 16 3 LEDs The first LED in each pair of LEDs indicates the status of the upper odd numbered port below the LEDs and the second LED in each pair indicates the status of the lower ...

Страница 23: ...mber Related Topics LED Indicators on page 8 Management Port LED This table describes the management port LEDs Description Color State Port is not provisioned Off Port is provisioned but administratively not operational Amber Port is linked up Green A port fault is detected or the port beacon has been provisioned by the operator Alternating green and amber Related Topics LED Indicators on page 8 C...

Страница 24: ...blue beacon 2 Table 7 Fan Tray ID LED Indicator Description Color State The fan tray needs attention Blinking blue Table 8 Fan Tray Fan Status LED Indicator Description Color State The fan tray is not receiving power the fans have stopped Off All fans are operating normally Green The fan tray has a failure Red Catalyst 6880 X Switch Hardware Installation Guide 12 OL 30827 02 Product Overview LED I...

Страница 25: ...ower Supply LED Indicators Description Color State LED AC input current is at acceptable level Solid green IN AC input current is outside valid range Blinking green IN DC output current is at acceptable level Solid green OUT DC output current is outside valid range Blinking green OUT Malfunction has occurred Solid red FAULT The power supply needs attention activated by operator Blinking blue ID Re...

Страница 26: ...acceptable level Solid green IN1 Primary DC input current is outside valid range Blinking green IN1 Secondary DC input current is at acceptable level Solid green IN2 Secondary DC input current is outside valid range Blinking green IN2 Output DC current is at acceptable level Solid green OUT Output DC current is outside valid range Blinking green OUT Power supply unit is functioning normally Off FA...

Страница 27: ...needs attention activated by operator Blinking blue ID Related Topics LED Indicators on page 8 Rear Panel Figure 9 Rear Panel Rear panel of the switch 1 Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 15 Product Overview Rear Panel ...

Страница 28: ...Catalyst 6880 X Switch Hardware Installation Guide 16 OL 30827 02 Product Overview Rear Panel ...

Страница 29: ...nstallation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning Read the installation instructions before connecting the system to the power source Statement 1004 Warning Site Requirements Planning a proper location for the switch and layout of the equipment rack or wiring closet i...

Страница 30: ...e of chips and failure of mechanical devices Extreme temperature fluctuations may also cause chips to become loose in their sockets Observe the following guidelines Ensure that the system is operating in an environment no colder than 32 F 0 C or no hotter than 104 F 40 C Ensure that the chassis has adequate ventilation Do not place the chassis within a closed in wall unit or on top of cloth which ...

Страница 31: ... 2 hours Measure the ambient air temperature at the chassis air intake grill and at the chassis air exhaust grill by positioning an external temperature probe approximately 1 inch 2 5 cm away from the grills If the ambient intake air temperature is less than 104 F 40 C the rack meets the intake air temperature criterion If the ambient intake air temperature exceeds 104 F 40 C the system might expe...

Страница 32: ...lectrical resistance thermal conductivity physical strength and size Extreme moisture buildup inside the system may result in electrical short circuit which may cause serious damage to the system Each system is rated to operate at 5 to 90 percent relative humidity with a humidity gradation of 10 percent per hour In storage a system can withstand 5 to 95 percent relative humidity Buildings in which...

Страница 33: ...prolonged exposure to high temperature or humidity may corrode the gold plated edge connectors and pin connectors on various components in the system To prevent corrosion avoid touching contacts on boards and cards and protect the system from extreme temperatures and moist salty environments EMI and Radio Frequency Interference EMI and radio frequency interference RFI from a system can adversely a...

Страница 34: ... ground the cables especially in new cable runs to a suitable and safe earth ground before connecting them to the module Caution If the wires exceed the recommended distances or if wires pass between buildings give special consideration to the effect of a lightning strike in your vicinity The electromagnetic pulse caused by lightning or other high energy phenomena can easily couple enough energy i...

Страница 35: ...em lockup and frequent system reboot situations by not using a system ground Installations that rely solely on system grounding that uses only an AC third prong ground run a substantially greater risk of equipment problems and data corruption than those installations that use both the AC third prong ground and a properly installed system ground Caution The following table lists some general ground...

Страница 36: ...commended Low Existing commercial building is not subject to natural environmental noise or man made industrial noise This building contains a standard office environment In all situations grounding practices must comply with Section 250 of the National Electric Code NEC requirements or local laws and regulations A 6 AWG grounding wire is preferred from the chassis to the rack ground or directly t...

Страница 37: ...ow the operating instructions Use the correct external power source Operate the product only from the type of power source indicated on the electrical ratings label If you are not sure of the type of power source required consult the Cisco Technical Assistance Center or a local electrician Use approved power cables only You have been provided with one or more power cables with your chassis power s...

Страница 38: ...6880 X chassis that has a bare metal hole as the banana plug connector also identified by the ground symbol next to the connector we recommend that you use a personal ESD grounding strap equipped with a banana plug If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap equipped with an alligator clip you must attach the system ground lug to the chassis in...

Страница 39: ...e Be aware when selecting a UPS that some UPS models that use ferroresonant technology can become unstable when operating with the Catalyst 6880 X switch power supplies which use power factor correction PFC This can cause the output voltage waveform to the switch to become distorted resulting in an undervoltage situation in the system The AC input power supply has a detachable power cord that allo...

Страница 40: ...ulations in the National Electrical Code NEC as well as any local codes The DC return must remain isolated from the system frame and the chassis DC I For DC power cables we recommend that you use commensurately rated high strand count copper wire cable Connection to the DC input power supply requires one earth ground cable one source DC and one source DC return The length of the cables depends on ...

Страница 41: ...lowing caution We strongly recommend that power cabling runs and other potential noise sources be located as far away as practical from LAN cabling that terminates on Cisco equipment In situations where this type of long parallel cable runs exist and cannot be separated by at least 3 3 feet 1 meter we recommend that you shield these potential noise sources To avoid interference the source should b...

Страница 42: ...ntamination Airflow 2 Power evaluation Input power type Power receptacles Depends on power supply Receptacle proximity to the equipment Dedicated separate circuits for redundant power supplies UPS for power failures DC systems Proper gauge wire and lugs 3 Grounding evaluation Circuit breaker size CO ground AC and DC powered systems 4 Catalyst 6880 X Switch Hardware Installation Guide 30 OL 30827 0...

Страница 43: ...iring RFI levels 6 For power receptacles depends on power supply verify that each power supply installed in the chassis has a dedicated AC source or DC source circuit Note For UPS for power failures refer to the power supply s kVA rating as a sizing criteria in determining the output required by the UPS Note Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 31 Preparing for Installati...

Страница 44: ...Catalyst 6880 X Switch Hardware Installation Guide 32 OL 30827 02 Preparing for Installation Site Preparation Checklist ...

Страница 45: ...n down into a series of tasks which are described in the following table Description Task Remove the switch from the packaging materials Save the packaging material for later use if you need to move the chassis Note Unpacking the switch The Catalyst 6880 X chassis can be rack mounted Installing the switch Construct and attach a system ground wire from the building earth ground to the system ground...

Страница 46: ... of security Statement 1017 Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit Statement 1028 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning To prevent personal injury or damage to the chassis never attempt to lift or tilt the chassis using the...

Страница 47: ...idelines The width of the rack measured between the two front mounting strips or rails must be one of the following measurements 17 5 inches 44 45 cm 17 75 inches 45 09 cm The depth of the rack measured between the front and rear mounting strips must be at least 19 25 inches 48 9 cm The rack must have sufficient vertical clearance to insert the chassis 8 75 inches 22 23 cm 5 RU Chassis height is s...

Страница 48: ...ystem to fail Note Unpacking the Switch Do not discard the shipping container when you unpack the switch Flatten the shipping cartons and store them with the pallet You will need these containers if you need to move or ship the switch in the future Note Check the contents of the accessory kit Verify that you received all listed equipment which should include the following Grounding lug and disposa...

Страница 49: ...the rack mount screws The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own Note The accessory kit also contains the following chassis installation kits Rack mount shelf kit The rack mount shelf kit is used to support the weight of the chassis Cable guides Two cable guides can be installed on the front of the chassis using the same sets of sc...

Страница 50: ...aded to accept either 10 32 or 12 24 screws Newer rack enclosure posts might not be prethreaded These rack enclosure posts require that you install 10 32 or 12 24 clip nuts or cage nuts to secure the rack mount screws The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own Note Before you install the shelf brackets determine the clearance betwe...

Страница 51: ...bracket 2 M4 flathead Phillips screws 6 Right rail 3 Procedure Step 1 Position the support flange of the left shelf bracket on the front of the left rail as shown in the figure Alternatively you can position the support flange of the left shelf bracket on the back of the left rail Step 2 Secure the shelf bracket to the rack by using four screws Catalyst 6880 X Switch Hardware Installation Guide OL...

Страница 52: ...e shelf so that it rests on the bottom flanges of the shelf brackets Extrusions on the bottom of the shelf should fit into openings in the flanges Step 6 Secure the shelf to the support flanges on the shelf brackets with two screws for each shelf bracket Installing the Shelf Brackets and Shelf 17 75 in 45 09 cm Opening Before You Begin Review the following illustration and table Figure 14 Installi...

Страница 53: ...ets with two screws for each shelf bracket Rack Mounting the Chassis The chassis are designed to be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Note Procedure Step 1 Before rack mounting the chassis determine if you need to move the L brackets so that the chassis is installed in one of the recommended positions Positioned so the front of the chassis is approximate...

Страница 54: ...sis is installed the front of the chassis is approximately flush with the front of the rack 2 Step 2 With a person standing at each side of the chassis each person supports the chassis by placing one hand in the handhold on the side of the chassis see figure above and using the other hand under the back of the chassis for balance Slowly lift the chassis together Avoid sudden twists or moves to pre...

Страница 55: ...k mount bracket holes and the rack post holes as shown in figure below Step 6 Install all eight 10 32 or 12 24 screws four on each side through the cable guide mounting holes rack mount L bracket holes rack post holes and into the clip nuts to secure the cable guides and the chassis to the rack post Tighten the screws securely Figure 16 Installing the Cable Mount Guides Cable guide 1 Catalyst 6880...

Страница 56: ...nd connecting the power supplies to source power For information on how to install and cable power supplies see the Installing Power Supplies on page 55 Connecting to the switch console port See Connecting the Switch Console Port on page 47 Connecting to the uplink ports Powering up the chassis and verifying the installation See Verifying Switch Chassis Installation on page 51 Catalyst 6880 X Swit...

Страница 57: ...M Power down the chassis before attaching the system ground In all situations grounding practices must comply with Section 250 of the National Electric Code NEC requirements or local laws and regulations A 6 AWG grounding wire is preferred from the chassis to the rack ground or directly to the common bonding network CBN The equipment rack should also be connected to the CBN with 6 AWG grounding wi...

Страница 58: ...d lug 1 Procedure Step 1 Use a wire stripping tool to remove approximately 0 75 inch 19 mm of the covering from the end of the grounding wire Step 2 Insert the stripped end of the grounding wire into the open end of the grounding lug Step 3 Crimp the grounding wire in the barrel of the grounding lug Verify that the ground wire is securely attached to the ground lug Step 4 Place the grounding wire ...

Страница 59: ...e Port This section describes how to connect to the supervisor engine console port from a terminal or modem The console port on the supervisor engine allows you to perform the following functions Configure the switch from the CLI Monitor network statistics and errors Configure SNMP agent parameters Download software updates to the switch or distribute software images residing in flash memory to at...

Страница 60: ...ml Installing SFP and SFP Transceiver Modules Before You Begin For cable specifications see Appendix B Connector and Cable Specifications Observe these precautions Class 1 laser product Statement 1008 Warning Do not remove the dust plugs from the SFP transceiver modules or the rubber caps from the fiber optic cable until you are ready to connect the cable The plugs and caps protect the module port...

Страница 61: ...p latch move it to the open unlocked position Step 4 Align the module in front of the slot opening and push until you feel the connector snap into place Figure 19 Installing an SFP Module in the SFP Transceiver Module Port Step 5 If the module has a bale clasp latch close it to lock the SFP transceiver module in place If you are inserting the SFP transceiver module in the lower ports you need to i...

Страница 62: ...nnector plug is send Tx and which is receive Rx Step 3 Insert a dust plug into the optical ports of the SFP transceiver module to keep the optical interfaces clean Step 4 If the module has a bale clasp latch pull the bale out and down to eject the module If you cannot use your finger to open the latch use a small flat blade screwdriver or other long narrow instrument to open it Step 5 Grasp the SF...

Страница 63: ...ics section on page 3 19 for further information When prestaging systems in a nonproduction environment we recommend that you run all diagnostic tests including the disruptive tests to prescreen the systems for any failures Tip Online Diagnostics The switch running Cisco IOS has many levels of online diagnostic capabilities The online diagnostics are divided into four categories Bootup Bootup diag...

Страница 64: ...Catalyst 6880 X Switch Hardware Installation Guide 52 OL 30827 02 Installing the Switch Online Diagnostics ...

Страница 65: ...53 Installing Power Supplies page 55 Removing Power Supplies page 59 Finding the Serial Number page 61 Power Supply Overview You can install two types of power supplies in the chassis C6880 X 3KW AC Input power supply Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 53 ...

Страница 66: ...using any of the following combinations Two AC input power supplies Two DC input power supplies One AC input power supply and one DC input power supply One AC input power supply leaving the blank cover on the other slot One DC input power supply leaving the blank cover on the other slot Catalyst 6880 X Switch Hardware Installation Guide 54 OL 30827 02 Installing and Removing Power Supplies Power S...

Страница 67: ...commended mode for operation Installing Power Supplies You follow the same steps to install the AC input and DC input power supplies but you must ground them differently Before You Begin The switch chassis must be installed in a cabinet or rack that is secured to the data center Remove the power supply from its shipping container and remove any packaging You need the following additional tools and...

Страница 68: ...power supply with one hand place your other hand under the power supply to support its weight and position the power supply with its back end at the open power supply bay See the figure for an example AC power supply is shown as an example DC power supply can be installed in the same way Step 5 Slide the unit all the way into the power supply bay until the release latch on the front of the power s...

Страница 69: ...pply cables If you are installing more than one DC input power supply each must be protected by a dedicated circuit breaker or a fuse that is sized according to the power supply input rating and the local or national electrical code requirements The power sources are rated as follows For North American AC input installations 20 A with 110 V or 220 V circuits For North American DC input installatio...

Страница 70: ... the LEDs by checking that each LED turns on for a couple of seconds Tip If the Fault LED is flashing red turn the power switch to standby labeled as 0 check the AC power connections on the power supply and the AC power source and then turn the power switch back on labeled as 1 The Input and Output LEDs for the connected power supplies should be green and the Fault LED should be off Connecting to ...

Страница 71: ...he terminal box and fasten with three screws Step 6 Install the four cables from the DC power supply to an DC power sources as follows 1 If the unconnected end of each power cable is not stripped of its insulation for the last 0 75 inches 19 mm use wire strippers to remove that amount of insulation 2 Attach the negative cables to the negative terminals of a DC power source and attach the positive ...

Страница 72: ...from their terminals Replace the terminal box cover Remove the power cables from the power source Step 3 Remove the power supply from the chassis as follows a Press the ejector latch on the left of the power supply b Pull the power supply partially out of the slot by its handle c Place your other hand under the unit to support its weight d Pull the power supply fully from the slot If you intend to...

Страница 73: ... serial number is located You can also use the show version privileged EXEC command to see the serial number Figure 24 Serial Number on the AC Power Supply Figure 25 Serial Number on the DC Power Supply Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 61 Installing and Removing Power Supplies Finding the Serial Number ...

Страница 74: ...Catalyst 6880 X Switch Hardware Installation Guide 62 OL 30827 02 Installing and Removing Power Supplies Finding the Serial Number ...

Страница 75: ... uplink ports to connect to other devices The chassis should only be operated with either a modular port card installed or a blank module installed in the half modular slots Description Port Card Model Multirate port card with standard tables This module has 16 10 Gigabit 1 Gigabit or 100BASE FX fiber optic slots which support 1 Gigabit SFPs 10 Gigabit SFP or 100BASE FX fiber optic modules C6880 X...

Страница 76: ...ta sheet http www cisco com c en us products collateral switches catalyst 6880 x switch data_sheet_c78 728228 html Modular Port Card LEDs For information on the modular port card LEDs see these sections SFP Port LEDs on page 10 Status LED on the Modular Port Card on page 9 ID LED on the Modular Port Card on page 10 Catalyst 6880 X Switch Hardware Installation Guide 64 OL 30827 02 Installing the Mo...

Страница 77: ...til you connect the cable The plugs and caps protect the module ports and cables from contamination and ambient light To prevent ESD damage follow your normal board and component handling procedures when connecting cables to the switch and other devices Installing a Modular Port Card Procedure Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Step 2 Loosen th...

Страница 78: ... the port card into the chassis Slide the port card into the slot until the back of the port card faceplate is flush with the chassis faceplate Figure 29 Installing the Modular Port Card Step 6 Close the latch on the extraction handle by pressing the lever until you hear a click and it latches Catalyst 6880 X Switch Hardware Installation Guide 66 OL 30827 02 Installing the Modular Port Card Instal...

Страница 79: ... devices Caution Procedure Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Step 2 Find the send Tx and receive Rx markings that identify the top of the SFP or SFP module On some SFP transceiver modules the send and receive Tx and Rx markings might be represented by arrows that show the direction of the connection Step 3 If the SFP or SFP transceiver module ...

Страница 80: ... and to an earth ground surface Step 2 If the module has a bale clasp latch use the SFP removal tool Use the optical cable release side of the tool and apply pressure to release the cable latch and disconnect the cable from the SFP transceiver module Figure 32 Removing the Cable from the SPF Module Catalyst 6880 X Switch Hardware Installation Guide 68 OL 30827 02 Installing the Modular Port Card R...

Страница 81: ...Port Card Step 4 Grasp the SFP or SFP transceiver module and carefully remove it from the slot Step 5 Place the SFP or SFP transceiver module in an antistatic bag or other protective environment Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 69 Installing the Modular Port Card Removing SFP or SFP Modules from the Modular Port Card ...

Страница 82: ... 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Figure 34 Attaching an ESD Strap Catalyst 6880 X Switch Hardware Installation Guide 70 OL 30827 02 Installing the Modular Port Card Removing a Modular Port Card ...

Страница 83: ...sing the Latch Step 5 Grasp the port card and carefully slide it out of the slot You can use the other hand too Figure 36 Removing the Port Card Step 6 Install a replacement port card or a blank module in the slot Step 7 Place the port card that you removed in an antistatic bag or other protective environment You can close the latch so it locks and use the handle to carry the port card module Note...

Страница 84: ...er This figure shows where the serial number is located You can also use the show version privileged EXEC command to see the serial number Figure 37 Serial Number on the Modular Port Card Catalyst 6880 X Switch Hardware Installation Guide 72 OL 30827 02 Installing the Modular Port Card Finding the Modular Port Card Serial Number ...

Страница 85: ...ay The fan tray is designed to be removed and replaced while the system is operating without presenting an electrical hazard or damage to the system You have 120 seconds to remove and insert of the fan tray under specified ambient operating temperatures Note The fans might still be turning when you remove the fan from the chassis Keep fingers screwdrivers and other objects away from the openings i...

Страница 86: ...an tray 1 Step 2 Loosen the fan tray captive installation screw by turning it counterclockwise Step 3 Grasp the fan tray and pull it outward gently move side to side if necessary to unseat the fan tray power connector from the backplane When removing the fan tray keep your hands and fingers away from the spinning fan blades Let the fan blades stop completely before you remove the fan tray Caution ...

Страница 87: ... on the chassis and then lift the fan tray up slightly aligning the top and bottom chassis guides Step 3 Push the fan tray into the chassis until the power connector seats in the backplane and the captive installation screw make contact with the chassis Step 4 Tighten the captive installation screw Related Topics Cooling with the Fan Tray on page 20 Catalyst 6880 X Switch Hardware Installation Gui...

Страница 88: ... 2 Verify that the FAN STATUS LED is green If the LED is red one or more of the fans are faulty If after several attempts the fans do not operate or if you experience trouble with the installation for instance if the captive installation screws do not align with the chassis holes contact a Cisco customer service representative for assistance Catalyst 6880 X Switch Hardware Installation Guide 76 OL...

Страница 89: ...rial number This figure shows where the serial number is located You can also use the show version privileged EXEC command to see the serial number Figure 40 Serial Number on the Fan Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 77 Replacing the Fan Tray Finding the Fan Serial Number ...

Страница 90: ...Catalyst 6880 X Switch Hardware Installation Guide 78 OL 30827 02 Replacing the Fan Tray Finding the Fan Serial Number ...

Страница 91: ...X switch is equipped with internal air temperature sensors that generate a minor alarm when triggered at 104 F 40 C and generate a major alarm when triggered at 131 F 55 C Note Temperature operating Chassis unpackaged 4 to 149 F 20 to 65 C Chassis in protective shipping package 40 to 158 F 40 to 70 C Temperature nonoperating and storage 0 9 F 0 5 C per minute hot to cold 0 59 F 0 33 C per minute c...

Страница 92: ...tional Organization for Standardization ISO 7779 Bystander position operating to an ambient temperature of 86 F 30 C Acoustic noise Physical characteristics Height 8 75 in 22 23 cm Width 17 35 in 44 07 cm Depth 23 in 58 42 cm Chassis requires 5 rack units RUs The Catalyst 6880 X switch is designed to install in standard 19 inch equipment racks that meet ANSI EIA 310 D IEC 60297 and ETS 300 199 sta...

Страница 93: ... 9 cm Weight 5 lb 2 27 kg Physical specifications 48 VDC nominal at 37 A in North America operating range 40 5 to 56 VDC 60 VDC nominal at 30 A for international operating range 55 to 72 VDC 85 to 264 VAC Input voltage range 47 to 63 Hz Input frequency range 40 A maximum at 48 VDC input voltage total of two inputs 45 A maximum at 40V input 20 A maximum at nominal line voltage 110 or 220 VAC Input ...

Страница 94: ...following table lists the specifications for the AC power cords that are available for the 3000 W AC input power supply The table also includes references to power cord illustrations All 3000 W power supply power cords Note Are 14 feet 4 3 meters in length Have an IEC60320 C19 appliance connector at one end Table 13 3000 W Power Supply AC Power Cords Power Cord Part Number and Reference Illustrati...

Страница 95: ...page 87 16 A 250 VAC NEMA 6 20 Japan North America Nonlocking Plug 200 to 240 VAC Operation Figure 51 CAB AC C6K TWLK Japan North America Locking Plug 200 to 240 VAC operation on page 88 16 A 250 VAC NEMA L6 20 Japan North America Locking Plug 200 to 240 VAC Operation Figure 52 CAB 7513AC Japan North America100 to120 VAC operation on page 89 20 A 125 VAC NEMA 5 20 Japan North America 100 to 120 VA...

Страница 96: ...The end of the cable that plugs into the chassis power supply has a C19 connector the other end of the cable that connects to the PDU has a C20 connector Catalyst 6880 X Switch Hardware Installation Guide 84 OL 30827 02 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 97: ...tina Figure 42 CAB AC 16A AUS Australia New Zealand Figure 43 UCSB CABL C19 BRZ Brazil Figure 44 CAB AC16A CH People s Republic of China Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 85 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 98: ...W EU Continental Europe Figure 46 CAB SABS C19 IND India Figure 47 CAB AC 2500W INT International Catalyst 6880 X Switch Hardware Installation Guide 86 OL 30827 02 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 99: ...gure 49 CAB 7513ACI Italy Figure 50 CAB AC 2500W US1 Japan North America Nonlocking Plug 200 to 240 VAC operation Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 87 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 100: ...re 51 CAB AC C6K TWLK Japan North America Locking Plug 200 to 240 VAC operation Catalyst 6880 X Switch Hardware Installation Guide 88 OL 30827 02 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 101: ...re 52 CAB 7513AC Japan North America100 to120 VAC operation Figure 53 CAB L520P C19 US North America Figure 54 CAB C19 CBN PDU Figure 55 CAB 7513ACSA South Africa Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 89 Technical Specifications 3000 W Power Supply AC Power Cords ...

Страница 102: ... 6 39 lb 2 90 kg Weight Operating Specification 250 cfm Airflow Chassis and Module Power and Heat Values DC Heat Diss BTU HR DC Input Power Watts AC Heat Diss BTU HR AC Input Power Watts Module Power Watts Module Current A Module Type Catalyst 6880 X Switch Hardware Installation Guide 90 OL 30827 02 Technical Specifications Fan Module Specifications ...

Страница 103: ... W 660 W 13 2 A Catalyst 6880 X 5 2321 BTU HR 680 W 2321 BTU HR 680 W 630 W 12 6 A Catalyst 6880 X LE 6 5 Includes fan tray 6 Includes fan tray Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 91 Technical Specifications Chassis and Module Power and Heat Values ...

Страница 104: ...Catalyst 6880 X Switch Hardware Installation Guide 92 OL 30827 02 Technical Specifications Chassis and Module Power and Heat Values ...

Страница 105: ...onnector Figure 57 RJ 45 Interface Cable Connector Category 5e Category 6 and Category 6a cables can store large levels of static electricity because of the dielectric properties of the materials used in their construction Always ground the cables especially in new cable runs to a suitable and safe earth ground before connecting them to the module Caution To comply with GR 1089 intrabuilding and l...

Страница 106: ...the optical connectors are clean before making the connections Contaminated connectors can damage the fiber and cause data errors Note Figure 58 LC Fiber Optic Connector Cables and Adapters SFP Module Cables For cabling specifications refer to the Cisco SFP and SFP Transceiver Module Installation Notes Each port must match the wave length specifications on the other end of the cable and the cable ...

Страница 107: ... 60 Four Twisted Pair Crossover Cable Schematic Figure 61 Two Twisted Pair Straight Through Cable Schematic Figure 62 Two Twisted Pair Crossover Cable Schematic Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 95 Module Connectors and Cable Specifications Cable Pinouts ...

Страница 108: ...o connect the switch console port to a terminal You can order the kit part number ACS DSBUASYN from Cisco Table 14 Console Port Signaling with a DB 9 Adapter Console Device RJ 45 to DB 9 Terminal Adapter Switch Console Port DTE Signal DB 9 Pin Signal CTS 8 RTS DSR 6 DTR RxD 2 TxD GND 5 GND GND 5 GND TxD 3 RxD DTR 4 DSR RTS 7 CTS Catalyst 6880 X Switch Hardware Installation Guide 96 OL 30827 02 Mod...

Страница 109: ...ection provides the signaling and pinouts for the console port in mode 2 The port mode switch in the out position Table 16 Port Mode 2 Signaling and Pinouts Port Mode Switch Out Console Device Console Port Input Output Pin signal Output 1 RTS 7 Output 2 DTR Input 3 RxD GND 4 GND GND 5 GND Output 6 TxD Input 7 DSR Input 8 CTS 8 Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 97 Modul...

Страница 110: ...tter the connection The best physical contact connectors have return losses greater than 40 dB although 20 to 30 dB is more common The connection quality depends on two factors the type of connector and the proper cleaning and connection techniques Dirty fiber connectors are a common source of light loss Keep the connectors clean at all times and keep the dust covers installed when the connectors ...

Страница 111: ...or view directly with optical instruments Statement 1051 Warning Procedure Step 1 Use a lint free tissue soaked in 99 percent pure isopropyl alcohol to gently wipe the faceplate Wait five seconds for the surfaces to dry and repeat Step 2 Remove any residual dust from the faceplate with clean dry oil free compressed air Step 3 Use a magnifying glass or inspection microscope to inspect the ferrule a...

Страница 112: ...Catalyst 6880 X Switch Hardware Installation Guide 100 OL 30827 02 Module Connectors and Cable Specifications How to Clean the Fiber Optic Connectors ...

Страница 113: ...assis Step 3 Place the front packing material and power supply packing material around the chassis Step 4 Place the power supplies in the spaces provided in the power supply packing material Step 5 Place the top packing material over the top of the chassis and power supplies Step 6 Place the rack mount kit and the accessory kit on the top packing material You must include the accessory kit for the...

Страница 114: ... over the top and seal with packing tape Step 9 Wrap three packing straps tightly around the top and bottom of the package to hold the outside carton and the bottom pallet together Figure 65 Final Package Catalyst 6880 X Switch Hardware Installation Guide 102 OL 30827 02 Repacking the Switch ...

Страница 115: ...stem Component Level page 104 Identifying Startup Problems page 104 Troubleshooting the Power Supply page 104 Troubleshooting the Fan Tray page 105 Status LED Indicators page 106 Contacting Cisco Customer Service page 106 Finding the Serial Number page 107 Getting Started When the initial system startup is complete verify the following Power supplies are supplying power to the system The fan tray ...

Страница 116: ...rtup Problems LEDs indicate all system states in the startup sequence By checking the LEDs you can determine when and where the system failed in the startup sequence Procedure Step 1 Turn on the power supplies You should immediately hear the system fan tray assembly begin to operate If you do not hear the fans operating see the Troubleshooting the Power Supply on page 104 section If you determine ...

Страница 117: ... is available install it in the second power supply bay and contact a customer service representative for further instructions Step 2 If you have a second power supply repeat Step 1 for this power supply What to Do Next If you are unable to resolve the problem or if you determine that either a power supply or backplane connector is faulty see Contacting Cisco Customer Service on page 106 Troublesh...

Страница 118: ...hreshold Minor Orange Syslog message and SNMP trap generated If major alarm and the overtemperature condition is not corrected the system shuts down after 5 minutes If minor alarm monitor the condition Redundant supervisor engine temperature sensor exceeds major or minor threshold Major Minor Red Orange Contacting Cisco Customer Service If you are unable to solve a startup problem after using the ...

Страница 119: ... Serial Number If you contact Cisco Technical Assistance you need to know the switch serial number The figure shows where the serial number is located You can also use the show version privileged EXEC command to see the serial number Figure 66 Serial Number on the Chassis Catalyst 6880 X Switch Hardware Installation Guide OL 30827 02 107 Troubleshooting Finding the Serial Number ...

Страница 120: ...Catalyst 6880 X Switch Hardware Installation Guide 108 OL 30827 02 Troubleshooting Finding the Serial Number ...

Страница 121: ...he Cisco USB console driver file from the Cisco com web site and unzip it You can download the driver file from the Cisco com site for downloading the switch software Note Step 2 If using 32 bit Windows XP double click the setup exe file in the Windows_32 folder If using 64 bit Windows XP double click the setup x64 exe file in the Windows_64 folder Step 3 The Cisco Virtual Com InstallShield Wizard...

Страница 122: ...m the Cisco com site for downloading the switch software Note Step 2 If using 32 bit Windows Vista or Windows 7 double click the setup exe file in the Windows_32 folder If using 64 bit Windows Vista or Windows 7 double click the setup x64 exe file in the Windows_64 folder Step 3 The Cisco Virtual Com InstallShield Wizard begins Click Next Step 4 The Ready to Install the Program window appears Clic...

Страница 123: ...ove Programs Step 2 Scroll to Cisco Virtual Com and click Remove Step 3 When the Program Maintenance window appears select the Remove radio button Click Next Uninstalling the Cisco Microsoft Windows Vista and Windows 7 USB Driver Before You Begin Disconnect the switch console terminal before uninstalling the driver Procedure Step 1 Run setup exe for Windows 32 bit or setup x64 exe for Windows 64bi...

Страница 124: ...tallShield Wizard Completed window appears click Finish Catalyst 6880 X Switch Hardware Installation Guide 112 OL 30827 02 Installing the USB Drivers Uninstalling the Cisco Microsoft Windows Vista and Windows 7 USB Driver ...

Отзывы: