18
2.3 Supported IPMI OEM Commands
01 1D - Get Power Off Inhibit
This command gets the value of the
Power Off Inhibit
flag.
For more information on the
Power Off Inhibit
flag, refer to the description
of "01 1C - Set Power Off Inhibit".
Request Data
-
B8
NetFn|LUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
4
1D
Command specifier
Response Data
-
BC
-
01
1
Completion code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
5
01
Response data length
6
Power Off Inhibit Flag: 0 no Inhibit, 1 Inhibit
01 20 - Set Next Power On Time
This command switches on a system at the given time independent of the stored
On/Off times in the configuration space.
The command takes effect only once.
You cancel a Power On time previously set with a 01 20 command by specifying
the Power On time “0” in a subsequent 01 20 command.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
20
Command specifier
5
00
Object ID
6:7
00 00
Value ID
8
04
Data length
9:12 Time (LSB first)