Cisco C880 M5 Configuration Guide
19
2.3 Supported IPMI OEM Commands
Response Data -
BC
-
01
1
Completion code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
Time (LSB first)
Time (UNIX-specific format) when the system switches on again. Time is NOT
stored in non-volatile memory. Resolution is 1 minute. After the system has
switched on, Time is set to 0 internally.
If Time == 0, the system is not switched on.
2.3.2
SCCI-compliant signaling command
10 02 - Write to System Display
This command is used to write characters to the LocalView display (if connected).
Request
Data
-
B8
NetFnlLUN: OEM/Group
-
10
Cmd : Command Group fan test
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
02
Command specifier
5
Object Index
: Line on display to write on.
6:7
Value ID
(not used)
8
Length
Number of characters to write, incremented by one.
(The string needs not to be null-terminated; characters
exceeding the length of a display line are truncated.)
9
Attribute:
0 = Write string left
aligned. 1 = Write string
centered.
10:10+n
Characters
to write to the display; string needs not to be null-
terminated.
Response
Data
-
BC
-
10
1
Completion code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first