Cisco C880 M5 Configuration Guide
15
2.3 Supported IPMI OEM Commands
The following sections describe the individual OEM-specific IPMI commands.
Description format
The OEM-specific IPMI commands contained in this chapter are described in the
format used by the IPMI standard for describing IPMI commands.
The IPMI standard describes the IPMI commands using command tables which
list the input and output parameters for each command.
You can find information on the IPMI standards on the Internet.
2.3.1
SCCI-compliant Power On/Off commands
01 15 - Get Power On Source
This command returns the reason for the most recent Power On. The possible reasons
are listed below.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
15
Command specifier
Response Data
-
BC
-
01
1
Completion code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
3
01
Data Length
4
Power on Source: Cause of last power on
Power on
Source
Description
0x00
Software or command
0x01
Power switch (on the front panel or keyboard)
0x02
Automatic restart after an AC power failure
0x03
Clock or timer (hardware RTC or software timer)
0x04
Automatic restart after fan failure shutdown
0x05
Automatic restart after critical temperature shutdown