Procedure
Step 1
Use a Phillips screwdriver to remove the zero touch provisioning (ZTP) reset button screw. Be careful not to
loose the screw.
Step 2
Use a straightened paperclip, thin non-metallic pin, or thin non-metallic pin no larger than 3/16 inches in
diameter and push the ZTP reset button for 0.5 seconds to initiate zero touch provisioning. (See the following
figure.)
Figure 43: Accessing the ZTP Reset Button
ZTP reset button
1
Push the ZTP reset button for more than 8 seconds to reboot (power cycle) the router; all LEDs will turn off
for approximately 5 seconds, and then the LEDs will reactivate. For information on LEDs, see
, on page 78
.
Step 3
Replace the reset button screw and use a Phillips screwdriver to tighten to 22 to 24 in. lbs (2.49 to 2.71 Nm).
Cisco ASR 901S Series Aggregation Services Router Hardware Installation Guide
68
OL-29732-01
Installing the Router
Enabling Zero Touch Provisioning on the Router