7-38
Cisco ASR 1000 Series Aggregation Services Routers Software Configuration Guide
OL-16506-10
Chapter 7 Configuring Call Home
Alert Group Trigger Events and Commands
—
—
%ASR1000_PEM-3-FANFAIL
3
The fan in slot (
slot
/
subslot
number) is encountering a failure
condition.
—
—
%ASR1000_PEM-6-FANOK
6
The fan in slot (
slot
/
subslot
number) is functioning properly.
—
—
%ASR1000_PEM-3-PEMFAIL
3
The PEM in slot (
slot
number) is
switched off or encountering a
failure condition.
—
—
%ASR1000_PEM-6-PEMOK
6
The PEM in slot (
slot
number) is
functioning properly.
—
—
%ENVIRONMENTAL-1-ALERT
1
Any sensor in fp/cc/rp has exceeded
a certain threshold and resulted in
this environmental alert.
—
ENVM
%ENVIRONMENTAL-1-SENSORFAIL
1
Any sensor in fp/cc/rp has failed
and resulted in this environmental
alert.
—
—
%ENVIRONMENTAL-1-SENSOROK
1
Any sensor in fp/cc/rp has
recovered and resulted in this
environmental alert.
Inventory
—
—
—
Inventory status should be provided
whenever a unit is cold-booted, or
when FRUs are inserted or
removed. This is considered a
noncritical event, and the
information is used for status and
entitlement. (Sent to TAC.)
CLI commands executed:
show platform
show inventory oid
show version
show diag all eeprom detail
—
SPA
HARDWARE_
REMOVAL
%ASR1000_OIR-6-REMSPA
6
SPA removed from subslot
(
slot
/
subslot
number) and the
interfaces are disabled.
—
SPA
HARDWARE_I
NSERTION
%ASR1000_OIR-6-INSSPA
6
SPA inserted in subslot (
slot
/
subslot
number).
—
CC/FP/RP
HARDWARE_
REMOVAL
%ASR1000_OIR-6-REMCARD
6
Card (cc/rp/fp) removed from slot
(
slot
number).
—
CC/FP/RP
HARDWARE_I
NSERTION
%ASR1000_OIR-6-INSCARD
6
Card (cc/rp/fp) inserted in slot (
slot
number).
Table 7-3
Call Home Alert Groups, Events, and Actions (continued)
Alert Group
Call Home
Trigger Event
Syslog Event
Severity
Description and CLI Commands
Executed