Chapter 1 Setting Up the ACE
Establishing a Console Connection on the ACE
1-2
Cisco 4700 Series Application Control Engine Appliance Administration Guide
OL-11157-01
Establishing a Console Connection on the ACE
You establish a direct serial connection between your terminal or a PC and the
ACE by making a serial connection to the console port on the rear panel of the
ACE. The ACE has one standard RS-232 serial port found on the rear panel that
operates as the console port. The integrated serial port uses a 9-pin male D-shell
connector. Use a straight-through cable to connect the switch to a DTE device,
such as a terminal or a PC. For instructions on connecting a console cable to your
ACE appliance, see the
Cisco Application Control Engine Appliance Hardware
Installation Guide
.
Any device connected to this port must be capable of asynchronous transmission.
Connection requires a terminal configured as 9600 baud, 8 data bits, hardware
flow control on, 1 stop bit, no parity.
Note
Only the Admin context is accessible through the console port; all other contexts
can be reached through Telnet or SSH sessions.
Once connected, use any terminal communications application to access the ACE
C LI
. The following procedure uses HyperTerminal for Windows.
To access the ACE by using a direct serial connection, perform the following
steps:
Step 1
Launch HyperTerminal. The Connection Description window appears.
Step 2
Enter a name for your session in the Name field.
Step 3
Click
OK
. The Connect To window appears.
Step 4
From the drop-down list, choose the COM port to which the device is connected.
Step 5
Click
OK
. The Port Properties window appears.
Step 6
Set the following port properties as follows:
•
Baud Rate = 9600
•
Data Bits = 8
•
Hardware Flow Control = On
•
Parity = none
•
Stop Bits = 1
Step 7
Click
OK