2-100
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
SW_VLAN Messages
Error Message
SW_VLAN-4-BAD_VLAN_CONFIGURATION_FILE_VERSION: VLAN configuration
file contained unknown file version [dec].
Explanation
The VLAN configuration file read by the VLAN manager contained an unrecognized
file version number, which might mean an attempt to regress to an older version of the VLAN
manager software. [dec] is the file version number.
Recommended Action
Find out more about the error by using the
show tech-support
privileged EXEC
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting IBM, see the
.
Error Message
SW_VLAN-4-BAD_VLAN_TIMER_ACTIVE_VALUE: Encountered incorrect VLAN
timer active value [chars].
Explanation
Because of a software error, a VLAN timer was detected as active when it should have
been inactive or as inactive when it should have been active. [chars] is the VLAN timer active value.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
SW_VLAN-4-EXT_VLAN_INTERNAL_ERROR: Extended VLAN manager received an
internal error [dec] from [chars] [chars].
Explanation
An unexpected error code was received by the VLAN manager from the extended-range
VLAN configuration software. [dec] is the error code. The first [chars] is the function, and the
second [chars] describes the error code.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the
show
tech-support
user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
.